Features
- Adjustable alarm threshold set points
- High / low battery voltage alarms
- ± Ground fault detection with alarm
- AC charger power loss
- High accuracy ± 0.2 VDC
- Open cell / AC charger malfunction alarm
No products in the cart.
The Arga Battery Monitor Panel Mount from Electroswitch monitors battery voltage and ground fault detection for DC systems. A LED display identifies alarm conditions in addition to audible alarms. Easily calibrate and set alarm thresholds through the front panel menu.
Alarm functions: battery voltage, ground fault detection, AC power loss, ripple voltage, ripple current, high impedance and predictive corrosion detection.
Remote monitoring and reporting is ideal for multiple and distant locations. The Arga Battery Monitor Panel Mount supports Serial DNP3.0, Modbus and RS485 communications.
Pricing and lead times may vary. Please request a quote, call us at (866) 650-3282, or send an Email to team@americanteledata.com for more information.
Call for Price
This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.
Compare
The only way to know if your stationary batteries will perform to specification is to test them regularly.
NERC standard PRC-005-2 requires that vented lead acid and nickel cadmium (NiCd) systems be discharge tested every six years and valve regulated lead acid (VRLA) batteries every three years. IEEE recommends load testing stationary flooded/vented lead acid and NiCd stationary batteries every five years and VRLA batteries every 12–18 months.
The SBS-2415S constant current load banks are an affordable way to perform easy and accurate IEEE450 (vented lead acid), IEEE1106 (NiCd) and IEEE1188 (VRLA) load tests.
These units are quick and easy to set up. They display the voltage, current and Ah removed from the string during the test. Since this is a constant current load bank, the user also does not have to adjust the current during the test.
These load banks come standard with multiple adjustable stop points and built-in protection to ensure that the batteries are never damaged due to over-discharge.
Built-in memory continuously records discharge data including: overall system voltage, current and individual cell voltages (when modules are installed).
Pricing and lead times may vary. Please request a quote, call us at (866) 650-3282, or send an Email to team@americanteledata.com for more information.


The only way to know if your stationary batteries will perform to specification is to test them regularly.
NERC standard PRC-005-2 requires that vented lead acid and nickel cadmium (NiCd) systems be discharge tested every six (6) years and valve regulated lead acid (VRLA) batteries every three (3) years. IEEE recommends load testing stationary flooded/vented lead acid and NiCd stationary batteries every five (5 )years and VRLA batteries every 12–18 months.
The SBS-1110S constant current load banks are an easy and affordable way to perform accurate IEEE450 (Vented Lead-Acid), IEEE1106 (Ni-Cad) and IEEE1188 (VRLA) load tests.
These units are quick and easy to set up. They display the voltage, current and Ah removed from the string during the test. Since this is a constant current load bank, the user also does not have to adjust the current during the test.
These load banks come standard with multiple adjustable stop points and built-in protection to ensure that the batteries are never damaged due to over-discharge
Pricing and lead times may vary. Please request a quote, call us at (866) 650-3282, or send an Email to team@americanteledata.com for more information.

The BHS Bridge Trolley allows a single person to change batteries for light battery applications. Coupled with our standard guidance track, the BT is easily pushed by hand for smooth and efficient change-outs.
Pricing and lead times may vary. Please request a quote, call us at (866) 650-3282, or send an Email to team@americanteledata.com for more information.
Select at least 2 products
to compare