, , ,

MA6UFL – MarineTuff Cat 6, U/FTP, 4 Pr 23 BC, FMPE Ins, LSZH, Indoor, LR certified


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Shipbuilding, in-cabin passenger Wi-Fi, high-bandwidth IPTV, PoE lighting, device charging stations, onboard security cameras, etc.

Physical Characteristics (Overall)

Conductor
AWG Stranding Material No. of Pairs
23 Solid BC – Bare Copper 4
Conductor Count: 8
Total Number of Pairs: 4
Insulation
Material Nominal Diameter
PO – Polyolefin (Foam) 1.35 mm
Color Chart
Number Color
Pair 1 White & Blue
Pair 2 White & Orange
Pair 3 White & Green
Pair 4 White & Brown
Inner Shield
Type Material
Tape Bi-Laminate (Alum+Poly)
Outer Shield
Drainwire Material Drainwire AWG
Tinned Copper 28 AWG
Outer Jacket
Material Nominal Diameter Diameter +/- Tolerance
LSZH – Low Smoke Zero Halogen (SHF1) 7.5 mm 0.3 mm

Construction and Dimensions

Min Elongation at Breakof Jacket: 125 %
Min Tensile Strength of Jacket: 9 MPa
Min Tensile Strength of Jacket Aged: 30 %
Min Elongation at Break of Jacket Aged: 30 %

Electrical Characteristics

Conductor DCR
Max. Conductor DCR Max DCR Unbalanced Between Pairs [%] Max. DCR Unbalanced Within Pair [%]
95 Ohm/km 4 % 2 %
Capacitance
Max. Capacitance Unbalance Max. Mutual Capacitance
160 pF/100m 56 pF/m
Insulation Resistance: 5000 MOhm.m
Impedance
Nominal Characteristic Impedance
100 Ohm
Delay
Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
45 ns/100m 77%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Min. TCL [dB] Min. ELTCTL [dB]
1 MHz 2.1 dB/100m 75.3 dB 72.3 dB 73.2 dB 70.2 dB 68 dB 65 dB 20 dB 40 dB 35 dB
4 MHz 3.8 dB/100m 66.3 dB 63.3 dB 62.4 dB 59.4 dB 56 dB 53 dB 23 dB 34 dB 23 dB
10 MHz 6 dB/100m 60.3 dB 57.3 dB 54.3 dB 51.3 dB 48 dB 45 dB 25 dB 30 dB 15 dB
16 MHz 7.6 dB/100m 57.2 dB 54.2 dB 49.6 dB 46.6 dB 43.9 dB 40.9 dB 25 dB 28 dB 10.9 dB
31.3 MHz 10.7 dB/100m 52.9 dB 49.9 dB 42.1 dB 39.1 dB 38.1 dB 35.1 dB 23.6 dB 25.1 dB 5.1 dB
62.5 MHz 15.5 dB/100m 48.4 dB 45.4 dB 32.9 dB 29.9 dB 32.1 dB 29.1 dB 21.5 dB 22 dB
100 MHz 19.9 dB/100m 45.3 dB 42.3 dB 25.4 dB 22.4 dB 28 dB 25 dB 20.1 dB 20 dB
125 MHz 22.5 dB/100m 43.8 dB 40.8 dB 21.4 dB 18.4 dB 26.1 dB 23.1 dB 19.4 dB 19 dB
200 MHz 29.1 dB/100m 40.8 dB 37.8 dB 11.6 dB 8.6 dB 22 dB 19 dB 18 dB 17 dB
250 MHz 33 dB/100m 39.3 dB 36.3 dB 6.3 dB 3.3 dB 20 dB 17 dB 17.3 dB 16 dB
Table Notes: Limits below 4 MHz are for information only. Reference standard: ISO/IEC 61156-5 ed. 2.0 (2009)
Coupling Attenuation Class: Type Ib
Transfer Impedance Class: Grade 2
Voltage
Voltage Rating [V]
72 V DC

Temperature Range

Installation Temperature Range: -5°C To +80°C
Operating Temperature Range: -40°C To +80°C

Mechanical Characteristics

Bending Test: Low temperature bending test -40 °C : No cracks
Pressure Test for Jacket: Test at high temperature IEC 60811-508 80±2 °C 4h : ? 50 %
Heat Stroke Test: Heat Shock test at (150±3°C ,1h) : No cracks
Bulk Cable Weight: 57.3 kg/km
Min. Bend Radius During Installation: 10*D

Standards

ISO/IEC Compliance: ISO/IEC 11801-2, IEC 60092-360
CENELEC Compliance: EN 50173-1
Data Category: Category 6
ANSI Compliance: ANSI/TIA 568.2-D (2018)
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4

Applicable Environmental and Other Programs

Environmental Space: Indoor

Suitability

Suitability – Indoor: Yes

Flammability, LS0H, Toxicity Testing

IEC Flammability: IEC 60332-1-2, IEC 60332-3-22
Fluorine Content Test IEC60684-2: HF ? 0.1%
IEC 60754-1 – Halogen Amount: HCL+HBr ? 0.5%
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: 10 µS/mm
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: 4.3
IEC 61034-2 – Smoke Density Min. Transmittance: 60%

Related Part Numbers

Footnote: *Ordering stock code will be created at the time of placing the order and the stock code will include cable part code, outer jacket color & putup length.

Product Notes

Notes: LR (Lloyd’s Register) certification

History

Update and Revision: Revision Number: 0.52 Revision Date: 12-12-2023

Select at least 2 products
to compare