Product Overview
| Construction Type: | Interconnect |
| Environmental Space: | Indoor/Outdoor |
| Suitable Applications: | Small, lightweight Flat Drop Cable offers an ideal solution for the smaller fiber counts that are needed in the final sections of an optical network, particularly in a fiber-to-the-premise (FTTx) installation |
Construction
| Fiber Type | Fiber Grade acc. ITU-T | Fiber Count |
|---|---|---|
| OS2 | G.657A2 | 2 |
| Fiber Color Coding: | TIA coding (Gxxxxxx.T): Blue, Orange |
| Cable Core Water Tight: | Yes |
| Bulk Cable Weight: | 14 kg/km |
Jacket Specifications
| Number of Jackets: | Single Jacket |
| Type of Armor: | Non-Armored |
Outer Jacket Specifications
| Material | Nominal Diameter | Ripcord |
|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 2.2 mm | No |
Optical Characteristics
| Max. Attenuation at 1310 nm: | 0.40 dB/km |
| Max. Attenuation at 1550 nm: | 0.30 dB/km |
| Max. Attenuation at 1625 nm: | 0.30 dB/km |
Mechanical Characteristics
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 25 mm | IEC 60794-2-10 |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 25 mm | IEC 60794-2-10 |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 450 N (101 lbf) | IEC 60794-2-10 |
| Cable Max. Tensile Strength Operation (Long Term) | IEC 60794-1-21-E1 | 150 N (34 lbf) | IEC 60794-2-10 |
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 5 kN/m | IEC 60794-2-10 |
Temperature Range
| Operating Temperature Range: | -40 °C to +70 °C |
| Installation Temperature Range: | -15 °C to +50 °C |
| Storage Temperature Range: | -40 °C to +70 °C |
Standards
| UL Rating/Flame Test: | Non-UL Rated |
| IEC Flammability: | IEC 60332-1-2 |
| IEC 60754-1 – Halogen Amount: | Zero |
| IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 10 µS/mm |
| IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
| IEC 61034-2 – Smoke Density Min. Transmittance: | 60% |
| CPR Euroclass: | Eca |
| REACH: | Compliant |
| ISO/IEC Compliance: | IEC 60794-1-1 |
| EU Directive 2011/65/EU (RoHS 2): | Compliant |
| UV/ Sunlight Protection: | Yes |
History
| Update and Revision: | Revision Number: 0.83 Revision Date: 12-14-2023 |








































Standard Cabinet - ES - 52U Height 30'' Width 48'' Depth Black - Mesh Contour Front/Rear - Great Lakes Data Racks and Cabinets
Standard Cabinet - ES - 44U Height 24'' Width 42'' Depth Black - Mesh Contour Front/Split Mesh Rear - Great Lakes Data Racks and Cabinets
Flaring & Insertion Tool 0.34 (FT-6) - Jonard
3/4" Coax Cable Cutter 0.91 (JIC-750) - Jonard
Compact Cable Slit & Ring Tool, (0 - 0.125") 0.08 (CSR-125) - Jonard
Buffer Tube Ring Tool 0.09 (BTR-6) - Jonard
RG59/6 & RG7/11 With Blade Stop 0.02 (UST-225) - Jonard
Standard Cabinet - ES - 52U Height 24'' Width 48'' Depth Winter White - Mesh Contour Front/Rear - Great Lakes Data Racks and Cabinets
Fluid Dispenser 220 Ml For Fiber Cleaning 0.09 (FD-220) - Jonard
Universal Cable Stripping Tool 0.23 (UST-500) - Jonard
Standard Cabinet - ES - 52U Height 24'' Width 48'' Depth Black - Mesh Contour Front/Rear - Great Lakes Data Racks and Cabinets