GIMKCF04 – Indoor bare fiber mini distribution cable LSZH jacket 4f SM OS2 G.657.A2. CPR Cca.


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Environmental Space: Indoor – Euroclass Cca
Suitable Applications: For indoor use in structured (premises) wiring systems: building backbone (riser) and/or horizontal cabling (Fibre To The Desk). Support all computer network applications such as FDDI, Gigabit Ethernet and ATM. Easy to install in ducts and tunnels.

Construction

Fiber Cable Construction
Fiber Grade acc. ITU-T Fiber Count
G.657A2 4
Fiber Color Coding: TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown
Cable Core Waterblocking: Waterblocking Aramid Yarns
Bulk Cable Weight: 8 kg/km

Outer Jacket Specifications

Outer Jacket
Material Nominal Diameter Ripcord
LSZH – Low Smoke Zero Halogen (Flame Retardant) 3.0 mm No
Table Notes: Standard color: Orange. Available colors: Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Black, Lime Green

Optical Characteristics

Max. Attenuation at 1310 nm: 0.40 dB/km
Max. Attenuation at 1550 nm: 0.30 dB/km
Max. Attenuation at 1625 nm: 0.30 dB/km

Mechanical Characteristics

Mechanical Tests
Description Tested Standard Requirement/Value According to Family Specification
Cable Min. Bend Radius Installation (Short Term) IEC 60794-1-21-E6 45 mm IEC 60794-2-20
Cable Min. Bend Radius Operation (Long Term) IEC 60794-1-21-E11 30 mm IEC 60794-2-20
Cable Max. Tensile Strength Installation (Short Term) IEC 60794-1-21-E1 150 N (34 lbf) IEC 60794-2-20
Cable Max. Crush Resistance Installation (Short Term) IEC 60794-1-21-E3 IEC 60794-2-20
Cable Max. Crush Resistance Operation (Long Term) IEC 60794-1-21-E3 IEC 60794-2-20

Temperature Range

Operating Temperature Range: 0 °C to +70 °C
Installation Temperature Range: -5 °C to +50 °C
Storage Temperature Range: -10 °C to +70 °C

Standards

IEC Flammability: IEC 60332-1-2
Reaction to Fire – Bundle Flame Test: IEC 60332-3-24
IEC 60754-1 – Halogen Amount: Zero
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: 10 µS/mm
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: 4.3
CPR Euroclass: Cca-s1a,d1,a1
REACH: Compliant
ISO/IEC Compliance: IEC 60794
EU Directive 2011/65/EU (RoHS 2): Compliant

History

Update and Revision: Revision Number: 0.16 Revision Date: 12-14-2023
SKU: GIMKCF04 Categories: , , ,