Product Overview
| Construction Type: | Multi Loose Tube |
| Environmental Space: | Outdoor |
| Suitable Applications: | For outdoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. Suitable for Direct Burial. |
Construction
| Fiber Type | Fiber Count | Subunit Color |
|---|---|---|
| OM3 | 96 | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black |
| Fiber Color Coding: | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua |
| Central Strength Member: | GRP |
| Cable Core Water Tight: | Yes |
| Cable Core Waterblocking: | Waterblocking Aramid Yarns + Tape |
| Bulk Cable Weight: | 87 kg/km |
SubUnit Specifications
| Number of Active Subunits: | 8 |
| Number of Subunit Positions: | 8 |
| Fibers Per Subunit: | 12 |
| Subunit Diameter: | 1.9 mm |
| Subunit Waterblocking: | Gel Filled |
Jacket Specifications
| Number of Jackets: | Single Jacket |
| Type of Armor: | Non-Armored |
Outer Jacket Specifications
| Material | Color | Nominal Diameter | Ripcord |
|---|---|---|---|
| PE – Polyethylene | Black | 10.5 mm | Yes |
Optical Characteristics
| Max. Attenuation at 1300 nm: | 0.9 dB/km |
| Max. Attenuation at 850 nm: | 2.9 dB/km |
Mechanical Characteristics
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 210 mm | IEC 60794-3-10 |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 158 mm | IEC 60794-3-10 |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 2700 N (607 lbf) | IEC 60794-3-10 |
| Cable Max. Tensile Strength Operation (Long Term) | IEC 60794-1-21-E1 | 900 N (202 lbf) | IEC 60794-3-10 |
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 15 kN/m | IEC 60794-3-10 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 7.5 kN/m | IEC 60794-3-10 |
| Cable Impact Resistance | IEC 60794-1-21-E4 | 10 J, 300 mm Radius, 3 Cycles | IEC 60794-3-10 |
| Cable Torsion Resistance | IEC 60794-1-21-E7 | 180°, 2 m, 10 cycles | IEC 60794-3-10 |
Temperature Range
| Operating Temperature Range: | -30 °C to +70 °C |
| Installation Temperature Range: | -5 °C to +50 °C |
| Storage Temperature Range: | -30 °C to +70 °C |
Standards
| UL Rating/Flame Test: | Non-UL Rated |
| REACH: | Compliant |
| ISO/IEC Compliance: | IEC 60794-1-1 |
| EU Directive 2011/65/EU (RoHS 2): | Compliant |
| UV/ Sunlight Protection: | Yes |
History
| Update and Revision: | Revision Number: 0.65 Revision Date: 12-12-2023 |








































45U 4-Post Adjustable Rack
Usb 2.0 Cable, Usb-A(M) To Usb-B(M), Beige, 15Ft
Telephone Surface Mount Box, Single Rj11, 4P4C, Loaded, Usoc, Ivory
Wallplate, Kitchen Mount, Single Rj11, 6P4C, Standard Finish, White
Cat6 Surface Mount Box, Dual Rj45, 8P8C, Loaded, 110Idc, 568A/B, White
6Port Keystone Wallplate Ivory Smooth Face SKU: ATDS101835IV
Usb 2.0 Cable, Usb-A(M) To Usb-B(M), Beige, 3Ft
4Port Keystone Wallplate Black Smooth Face SKU: ATDS101834BK
Duplex Adapter, 4P4C, Straight-Wired, White
41U Knockdown 4-Post Open Frame Rack
6" Wire Stripper Prier, 22~10AWG (0.6~2.6mm) SKU: ATDS250117
Cat6 Tooless Smb, Single Rj45, 8P8C, 110Idc, 568A/B, White