Product Overview
| Suitable Applications: | Indoor |
Fiber Specifications
| Fiber Type: | OS2 |
| Fiber Core Diameter: | 8.2/125?m µm |
| Buffer Material: | PVC |
| Buffer Diameter: | 900 µm |
| Fiber Count: | 2 |
| Fiber Color Coding: | TIA-598-D |
Outer Jacket Specifications
| Strength Member: | Aramid Yarns |
| Jacket Material: | PVC – Polyvinyl Chloride |
| Nom. Diameter: | 0.078 in (2.0 mm) |
| Color: | Yellow |
| Wavelength | 1310 nm | 1550 nm |
|---|---|---|
| Max. Attenuation | 0.50 dB/km | 0.50 dB/km |
| Mode Field Diameter | 9.2 µm | 10.4 µm |
| 1 Gigabit Ethernet Performance | 5000 m | – |
| 10 Gigabit Ethernet Performance | 10000 m | 50000 m |
Mechanical Characteristics
| Min. Bend Radius During Installation: | 15x Cable OD |
| Min. Bend Radius During Operation: | 10x Cable OD |
| Max. Tensile Strength During Installation: | 222 N (50 lbf) |
| Max. Tensile Strength During Operation: | 67 N (15 lbf) |
| Crush Resistance: | 35 N/cm |
| Bulk Cable Weight: | 2.3 lbs/1000ft |
Temperature Range
| Installation Temperature Range: | 0°C to +60°C |
| Operating Temperature Range: | 0°C to +70°C |
| Storage Temperature Range: | -40°C to +70°C |
Standards and Compliance
| Environmental Suitability: | Indoor |
| Sustainability: | CA Prop 65 |
| Flammability / Reaction to Fire: | OFNP, FT6 |
| NEC / UL Compliance: | OFNP |
| CEC / C(UL) Compliance: | FT6 |
| ICEA Compliance: | S-83-596 |
| TIA/EIA Compliance: | ANSI/ICEA S-83-596 |
History
| Update and Revision: | Revision Number: 0.70 Revision Date: 04-08-2022 |
Part Numbers
| Item # | Color | Putup Type |
|---|---|---|
| FISI002P0 | Yellow | Reel |