| Construction Type: | Multi Loose Tube |
| Environmental Space: | Indoor/Outdoor |
| Suitable Applications: | For outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. Suitable for Direct Burial. |
Construction
| Fiber Type | Fiber Count | Subunit Color |
|---|---|---|
| OM3 | 12 | Blue, Orange, Filler, Filler, Filler, Filler, Filler |
| Fiber Color Coding: | TIA-598-D |
| Buffer Material |
|---|
| PBT Polybutylene Terephthalate |
| Central Strength Member: | GRP |
| Cable Core Waterblocking: | Waterblocking Yarns + Tape |
| Bulk Cable Weight: | 180 kg/km |
SubUnit Specifications
| Fibers Per Subunit: | 6 |
| Subunit Waterblocking: | Gel Filled |
Jacket Specifications
| Number of Jackets: | Single Jacket |
| Type of Armor: | Corrugated Steel Tape |
Outer Jacket Specifications
| Material | Color | Nominal Diameter | Nominal Wall Thickness |
|---|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | Black | 12.4 mm | 1.8 mm |
| Number of Ripcords: | 2 |
Optical Characteristics
| Fiber Core Diameter: | 50 µm |
| Max. Attenuation at 1300 nm: | 1.0 dB/km |
| Max. Attenuation at 850 nm: | 3.0 dB/km |
Mechanical Characteristics
| Description | Tested Standard | Requirement/Value |
|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E11 | 20 x Cable OD |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 10 x Cable OD |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 2000 N (450 lbf) |
| Cable Max. Tensile Strength Operation (Long Term) | IEC 60794-1-21-E1 | 600 N (135 lbf) |
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 1000 N/100mm |
Temperature Range
| Operating Temperature Range: | -40 °C to +70 °C |
| Storage Temperature Range: | -40 °C to +70 °C |
Standards
| IEC Flammability: | IEC 60332-1-2 |
| IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 10 µS/mm |
| IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
| IEC 61034-2 – Smoke Density Min. Transmittance: | IEC 61034?2 |
| ISO/IEC Compliance: | IEC 60793-1-1, IEC 60794-1-1 |
| RoHS: | Yes |
| EU Directive 2011/65/EU (RoHS 2): | Compliant |
| UV/ Sunlight Protection: | Yes |
History
| Update and Revision: | Revision Number: 0.31 Revision Date: 12-21-2023 |








































6U Shallow Depth Wall Cabinet
24U 4-Post Adjustable Rack
LAN Station LCD Monitor Mount
4Port Keystone Wallplate White Smooth Face SKU: ATDS101834WT
Training Table Power/Data Conversion Kit
9U Shallow Depth Wall Cabinet
2Port Keystone Wallplate White Smooth Face SKU: ATDS101832WT
Cat 5E RJ45 110 Type Keystone Jack Green SKU: ATDS101602GN
12U Shallow Depth Wall Cabinet
1U 12" Component Shelf - 2 pack