Product Overview
| Suitable Applications: | Instrumentation and computer cable; For EIA RS-232 data transmission applications |
Physical Characteristics (Overall)
| AWG | Stranding | Material | No. of Conductors |
|---|---|---|---|
| 24 | 7×32 | TC – Tinned Copper | 6 |
| Conductor Count: | 6 |
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|---|---|
| PE – Polyethylene (Foam) | 1.12 mm | 0.05 mm |
| Number | Color |
|---|---|
| Wire 1 | Black |
| Wire 2 | White |
| Wire 3 | Red |
| Wire 4 | Green |
| Wire 5 | Brown |
| Wire 6 | Blue |
| Type | Material | Material Trade Name | Thickness of Foil | Drainwire Material | Drainwire AWG |
|---|---|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 9 / 12 µm | TC – Tinned Copper | AWG24/7 |
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 6.6 mm | 1.3 mm |
Construction and Dimensions
| Description | Filler |
|---|---|
| 1 center filler and 6 wires twisted to cable core | Cotton (White) |
Electrical Characteristics
| Nominal Conductor DCR | Nominal Outer Shield DCR |
|---|---|
| 82 Ohm/km | 59.1 Ohm/km |
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
|---|---|
| 108.3 pF/m | 213.3 pF/m |
| Frequency [MHz] | Nominal Characteristic Impedance |
|---|---|
| N/A | 75 Ohm |
| Element | Max. Recommended Current [A] |
|---|---|
| Conductor(s) | 1.75 Amps per Conductor |
| Voltage Rating [V] |
|---|
| 300 V |
Temperature Range
| Installation Temperature Range: | -15°C To +70°C |
| Storage Temperature Range: | -45°C To +70°C |
| Operating Temp Range (Flexible Install): | -15°C To +70°C |
| Operating Temp Range (Fixed Install): | -45°C To +80°C |
Mechanical Characteristics
| Oil Resistance: | IEC 60811-404 |
| Max. Pull Tension: | 150 N |
| Min. Bend Radius During Installation: | 64 mm |
Standards
| CPR Euroclass: | Cca-s1,d1,a1 |
| CENELEC Compliance: | EN 50290-2-20 |
Applicable Environmental and Other Programs
| Environmental Space: | Indoor – Euroclass Cca |
Suitability
| Suitability – Indoor: | Yes |
| Suitability – Non-Halogenated: | Yes |
| Suitability – Sunlight Resistance: | Yes |
Flammability, LS0H, Toxicity Testing
| IEC Flammability: | IEC 60332-1-2 |
| IEC 60754-1 – Halogen Amount: | Zero |
| IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 2.5 µS/mm |
| IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
| IEC 61034-2 – Smoke Density Min. Transmittance: | 60% |
History
| Update and Revision: | Revision Number: 0.35 Revision Date: 02-15-2024 |








































Vented Steel Blanking Panel - RABPSV1 (1U, Single)
SC/UPC Singlemode Duplex Fiber Optic Coupler with Flange, Blue SKU: ATDS105120
Fiber in a Box Singlemode Riser Blend Simple Yellow Jacket 2000ft/610m - EF-OS2R-SIM-WT
DB25 Male Solder Cup Connector SKU: ATDS273005
75Ft Cat5E UTP Ethernet Network Booted Cable Green SKU: ATDS100510GN
1Ft Cat 8 U/FTP Slim Ethernet Network Cable Purple 30AWG