9265 – Composite ENG, EFP and CCTV


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Physical Characteristics (Overall)

Conductor
Element AWG Stranding Material Nominal Diameter No. of Pairs No. of Coax
Coax(es) 22 Stranded BC – Bare Copper 0.03 in 1
Pair(s) 22 7×30 TC – Tinned Copper 0.03 in 1
Total Number of Pairs: 1
Insulation
Element Material Nominal Diameter
Coax(es) PE – Polyethylene (Foam) 0.146 in
Pair(s) PVC – Polyvinyl Chloride 0.054 in
Color Chart
Number Color
1 Black
2 Red
Inner Shield
Element Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire Diameter Drainwire AWG Drainwire Construction n x D
Coax(es) Braid Bare Copper (BC) 95% TC – Tinned Copper 0.03 in 22 7×30
Pair(s) Tape Bi-Laminate (Alum+Poly) Beldfoil® (Z-Fold®) 100%
Outer Jacket
Material Nominal Diameter
PVC – Polyvinyl Chloride 0.47 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR Conductor Resistance Nominal Inner Shield DCR Nominal Outer Shield DCR
15 Ohm/1000ft 2.6 Ohm/1000ft 11 Ohm/1000ft
Capacitance
Element Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Shield
Coax(es) 51 pF/ft 17.3 pF/ft
Pair(s) 95.5 pF/ft
Inductance
Nominal Inductance
0.09 µH/ft
Impedance
Element Nominal Characteristic Impedance
Coax(es) 75 Ohm
High Frequency (Nominal/Typical)
Element Frequency [MHz] Nom. Insertion Loss
Coax(es) 1 MHz 0.3 dB/100ft
5 MHz 0.7 dB/100ft
10 MHz 1 dB/100ft
50 MHz 2.1 dB/100ft
100 MHz 3 dB/100ft
Delay
Element Nominal Delay Nominal Velocity of Propagation (VP) [%]
Coax(es) 1.3 ns/ft 78%
Voltage
UL Voltage Rating
30 V RMS
Electrical Characteristics Notes: Coax Nominal Voltage Breakdown Jacket (Shield to Ground) = 22kV RMS

Temperature Range

Non-UL Temp Rating: 60°C
Operating Temperature Range: -40°C To +60°C

Mechanical Characteristics

Bulk Cable Weight: 58 lbs/1000ft
Max. Pull Tension: 68 lbs
Min. Bend Radius/Minor Axis: 2.5 in

Standards

NEC/(UL) Compliance: CL2
UL AWM Style Compliance: AWM 20006
CPR Euroclass: Eca
RG Type: 59

Applicable Environmental and Other Programs

Environmental Space: Indoor (Not Riser or Plenum)
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/11/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: Yes
EU CE Mark: No
MII Order #39 (China RoHS): Yes

Suitability

Suitability – Indoor: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: UL1685 UL Loading
UL voltage rating: 30 V RMS

Plenum/Non-Plenum

Plenum (Y/N): No

Related Part Numbers

Variants
Item # Color Put-Up Type Length UPC
9265 010500 Black Reel 500 ft 612825226017
9265 0101000 Black Reel 1,000 ft 612825226000
Footnote: C – CRATE REEL PUT-UP.

Product Notes

Notes: Simaese Type Construction.

History

Update and Revision: Revision Number: 0.355 Revision Date: 05-05-2023