88741 – Audio/Control/Instrumentation, (2 pr) 22 AWG (7×30) TC, FEP/FEP, CMP


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: extreme high/low temperature environments; chemical resistant; outdoor and burial applications; low voltage analog signals (4-20ma, 0-10v, …); low voltage digital control (24v, …); line level audio; voice communications; panel wiring

Physical Characteristics (Overall)

Conductor
AWG Stranding Material No. of Pairs
22 7×30 TC – Tinned Copper 2
Conductor Count: 4
Total Number of Pairs: 2
Insulation
Material Nominal Wall Thickness
FEP – Fluorinated Ethylene Propylene 0.007 in
Color Chart
Number Color
1 Black & Red
2 Black & White
Outer Shield
Material
No Shield
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
FEP – Fluorinated Ethylene Propylene 0.169 in 0.009 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR Nominal Conductor Loop DCR
16 Ohm/1000ft 32 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Conductor
17 pF/ft
Inductance
Nominal Inductance
0.15 µH/ft
Impedance
Nominal Characteristic Impedance
88 Ohm
Current
Max. Recommended Current [A]
3.3 Amps per Conductor at 25ºC (10°C Temperature Rise)
Voltage
UL Voltage Rating
300 V RMS

Temperature Range

Operating Temperature Range: -70°C To +200°C

Mechanical Characteristics

Bulk Cable Weight: 16 lbs/1000ft
Max. Pull Tension: 18 lbs
Min. Bend Radius/Minor Axis: 1.75 in

Standards

NEC Articles: Article 800
NEC/(UL) Compliance: CMP
CEC/C(UL) Compliance: CMP

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/11/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes
MII Order #39 (China RoHS): Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: NFPA 262
CSA Flammability: FT6
UL voltage rating: 300 V RMS

Plenum/Non-Plenum

Plenum (Y/N): Yes

Related Part Numbers

Non-Plenum Number: 8741

History

Update and Revision: Revision Number: 0.193 Revision Date: 12-22-2023

Select at least 2 products