Product Overview
| Suitable Applications: | class 200 magnet wire |
Construction Details
| Element | No. of Elements | Size | Stranding | Material |
|---|---|---|---|---|
| Conductor(s) | 1 | 20 | Solid | BC – Bare Copper |
| Material | Nom. Thickness | Nom. Insulation Diameter |
|---|---|---|
| Polyester | 0.002 in (0.051 mm) | 0.0351 in (0.892 mm) |
| Overall Cable Diameter (Nominal): | 0.035 in (0.89 mm) |
Electrical Characteristics
| Nom. Conductor DCR | Max. Current |
|---|---|
| 10.1 Ohm/1000ft | Single conductor in free air @ 30ºC: 1.5 A |
| Breakdown Voltage |
|---|
| 5400 V Minimum (at Room Temperature) |
Mechanical Characteristics
| Operating |
|---|
| 200°C |
| Stationary Min. | Installation Min. |
|---|---|
| 0.14 in (3.6 mm) | 0.14 in (3.6 mm) |
| Max. Pull Tension: | 12.4 lbs (5.62 kg) |
| Bulk Cable Weight: | 3.2 lbs/1000ft |
Standards and Compliance
| Sustainability: | CA Prop 65 |
| Military Compliance: | J-W-1177/14 |
| European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
History
| Update and Revision: | Revision Number: 0.471 Revision Date: 01-20-2023 |
Part Numbers
| Item # | Color | Putup Type | Length | UPC |
|---|---|---|---|---|
| 8076 | None | Reel | 1 ft | 612825194583 |