Product Overview
| Suitable Applications: | Digital multi-modulation cable used in professional studios for the transmission of analogue and digital audio signals.; Designed to meet the requirements of the AES/EBU specification |
Physical Characteristics (Overall)
| AWG | Stranding | Material | Cross Section | Construction n x D | No. of Pairs |
|---|---|---|---|---|---|
| 24 | 7×32 | BC-OFHC – Oxygen-Free Bare Copper (High Conductivity) | 0.22 mm² | 7×0.20 mm | 8 |
| Conductor Count: | 16 |
| Total Number of Pairs: | 8 |
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|---|---|
| PE – Polyethylene (Foam) | 1.45 mm | 0.03 mm |
| Number | Color |
|---|---|
| Pairs 1 t/m 8 | White & Blue |
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
|---|---|---|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | Stranded tinned copper | 24 | 7×0.20 mm |
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 3.5 mm | 0.1 mm |
| Table Notes: | Elements are numbered for identification |
| Type | Material | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
|---|---|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | TC – Tinned Copper | 24 | Stranded |
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 14.5 mm | 1.2 mm |
Construction and Dimensions
| Description |
|---|
| 8 pairs + drainwire stranded tinnend copper (AWG24)(7×0.20mm) + Filler |
Electrical Characteristics
| Nominal Conductor DCR |
|---|
| 86 Ohm/km |
| Nom. Capacitance Conductor to Conductor |
|---|
| 40 pF/m |
| Frequency [MHz] | Nominal Characteristic Impedance | Nominal Characteristic Tolerance |
|---|---|---|
| 0.1 – 6 | 110 Ohm | 15 Ohm |
| Nominal Velocity of Propagation (VP) [%] |
|---|
| 80% |
Temperature Range
| Other Temp Range: | -30-+70 °C |
Mechanical Characteristics
| Min. Bend Radius During Installation: | 200 mm |
| Min. Bend Radius During Operation: | 145 mm |
Standards
| CPR Euroclass: | Cca-s1,d1,a1 |
Applicable Environmental and Other Programs
| Environmental Space: | Indoor – Euroclass Cca |
| EU Directive 2011/65/EU (RoHS 2): | Yes |
Flammability, LS0H, Toxicity Testing
| IEC Flammability: | IEC 60332-1-2 |
| IEC 60754-1 – Halogen Amount: | Zero |
| IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 2.5 µS/mm |
| IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
| IEC 61034-2 – Smoke Density Min. Transmittance: | 60% |
Related Part Numbers
| Item # | Color | Put-Up Type | Length |
|---|---|---|---|
| 70059LW.00500 | Violet | Reel | 500 m |
History
| Update and Revision: | Revision Number: 0.35 Revision Date: 01-15-2024 |