Product Overview
| Suitable Applications: | OSDP Readers, RS-485, Serial Data, Access Control |
Construction Details
| No. of Elements | Stranding | Material | Notes |
|---|---|---|---|
| 2 | 7×32 | TC – Tinned Copper | Twisted Pair Configuration |
| Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|
| FEP – Fluorinated Ethylene Propylene (Foam) | 0.025 in (0.64 mm) | 0.074 in (1.9 mm) | White/Blue Stripe & Blue/White Stripe |
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Aluminum | 100% | 24 AWG (7×32) TC |
| Material | Nom. Thickness | Nom. Diameter |
|---|---|---|
| Flamarrest® | 0.015 in (0.38 mm) | 0.186 in (4.72 mm) |
| Overall Cable Diameter (Nominal): | 0.186 in (4.72 mm) |
Electrical Characteristics
| Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Characteristic Impedence | Nom. Velocity of Prop. |
|---|---|---|---|
| 24 Ohm/1000ft | 13 pF/ft (43 pF/m) | 120 Ohm | 76% |
| UL Voltage Rating |
|---|
| (300 V (CMP)) |
Mechanical Characteristics
| UL Temperature | Operating |
|---|---|
| 60°C | -20°C to +60°C |
| Stationary Min. |
|---|
| 1.86 in (47.2 mm) |
| Max. Pull Tension: | 28 lbs (13 kg) |
| Bulk Cable Weight: | 16 lbs/1000ft |
Standards and Compliance
| Environmental Suitability: | Indoor – Plenum, Indoor |
| Flammability / Reaction to Fire: | CMP, FT6, NFPA 262 |
| NEC / UL Compliance: | Article 800 |
| European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance: | China RoHS II (GB/T 26572-2011) |
| Plenum Number: | 6640FD |
History
| Update and Revision: | Revision Number: 0.24 Revision Date: 02-15-2024 |