Product Overview
| Suitable Applications: | Intercom/PA Systems, Sound/Audio Systems, Control Systems |
Physical Characteristics (Overall)
| AWG | Stranding | Material | No. of Conductors |
|---|---|---|---|
| 18 | 7×26 | BC – Bare Copper | 2 |
| Conductor Count: | 2 |
| Type | Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness |
|---|---|---|---|---|
| Insulation | LSZH – Low Smoke Zero Halogen (Flame Retardant) | 1.72 mm | 0.05 mm | 0.25 mm |
| Number |
|---|
| Wire 1 |
| Wire 2 |
| Material | Nominal Diameter | Nominal Wall Thickness | Ripcord |
|---|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 5.5 mm | 1.0 mm | Yes |
| Table Notes: | Ripcord provided under sheath |
Construction and Dimensions
| Description |
|---|
| 2 wires twisted |
Electrical Characteristics
| Nominal Conductor DCR |
|---|
| 21.3 Ohm/km |
| Nom. Capacitance Conductor to Conductor |
|---|
| 100 pF/m |
| Voltage Rating [V] |
|---|
| 300 V |
Temperature Range
| Installation Temperature Range: | -20°C To +70°C |
| Storage Temperature Range: | -30°C To +70°C |
| Operating Temperature Range: | -20°C To +70°C |
Mechanical Characteristics
| Max. Pull Tension: | 90 N |
| Min. Bend Radius During Installation: | 55 mm |
| Min Setting Radius: | 28 mm |
Standards
| CPR Euroclass: | Cca-s1a,d1,a1 |
Applicable Environmental and Other Programs
| Environmental Space: | Indoor – Euroclass Cca |
Flammability, LS0H, Toxicity Testing
| IEC Flammability: | IEC 60332-1-2 |
| IEC 60754-1 – Halogen Amount: | Zero |
| IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 2.5 µS/mm |
| IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
| IEC 61034-2 – Smoke Density Min. Transmittance: | 80% |
Related Part Numbers
| Item # | Color | Put-Up Type | Length | EAN |
|---|---|---|---|---|
| 4300ULW.00500 | Gray | Reel | 500 m | 8719605177711 |
History
| Update and Revision: | Revision Number: 0.64 Revision Date: 02-15-2024 |