3076ELS – Profibus PA, 1PR #18 Str TC, PO ins, OS, LSNH Jkt, 300V SWA


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Profibus PA or Foundation FieldBus PA exposure to rodent, crush, or cut through force, harsh environment, outdoors, where multiple cable runs are required, data transmission applications such as Profibus DP or PA, Instrumentation and computer cable, etc. exposure to temperature extremes, humidity/moisture, dust, and oil.

Physical Characteristics (Overall)

Conductor
AWG Stranding Material
18 7×26 TC – Tinned Copper
Conductor Count: 2
Total Number of Pairs: 1
Insulation
Material Nominal Diameter Diameter +/- Tolerance Nominal Wall Thickness
PE – Polyethylene 2.55 mm 0.05 mm 0.67 mm
Color Chart
Number Color
Option .00 with blue inner- and outerjacket White & Black
Option .02 with yellow inner- and outerjacket White & Black
Option .03 with orange inner- and outerjacket White & Black
Option .05 with blue inner- and orange outer jacket White & Black
Option .07 with orange inner- and black outer jacket Orange & Blue
Inner Shield
Type Material Drainwire Material Drainwire AWG
Tape Bi-Laminate (Alum+Poly) TC – Tinned Copper AWG20/7
Inner Jacket
Material Nominal Diameter Nominal Wall Thickness
LSZH – Low Smoke Zero Halogen (Flame Retardant) 7.5 mm 1.15 mm
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
LSZH – Low Smoke Zero Halogen (Flame Retardant) 13 mm 1.85 mm

Construction and Dimensions

Armor
Type of Armor Material Thickness of Armoring Wires Coverage Percentage
Steel Wire Armoring Galvanized steel wire 0.9 mm Min. 95%

Electrical Characteristics

Conductor DCR
Max. Conductor DCR Max. Outer Shield DCR
20.5 Ohm/km 26 Ohm/km
Capacitance
Max. Capacitance Conductor to Conductor Max. Capacitance Conductor to Shield Max. Capacitance Unbalance
80 pF/m 155 pF/m 4 pF/m
Inductance
Nominal Inductance
0.62 uH/m
Impedance
Frequency [MHz] Nominal Characteristic Impedance Nominal Characteristic Tolerance
0.03125 MHz 100 Ohm 5 Ohm
Delay
Nominal Velocity of Propagation (VP) [%]
66%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation)
0.01 MHz 0.2 dB/100m
0.039 MHz 0.3 dB/100m
0.1 MHz 0.6 dB/100m
0.5 MHz 2.8 dB/100m
1 MHz 3.7 dB/100m
Voltage
Voltage Rating [V]
300 V

Temperature Range

Installation Temperature Range: -15°C To +80°C
Storage Temperature Range: -45°C To +80°C
Operating Temp Range (Flexible Install): -15°C To +80°C
Operating Temp Range (Fixed Install): -45°C To +80°C

Mechanical Characteristics

Oil Resistance: IEC 60811-404
Min. Bend Radius During Installation: 260 mm

Standards

ISO/IEC Compliance: IEC 61158-2
CPR Euroclass: Eca
CENELEC Compliance: EN 50290-2-27, EN 50288-7

Applicable Environmental and Other Programs

Environmental Space: Indoor, Indoor/Outdoor, Outdoor, Indoor/Outdoor – Euroclass Eca

Suitability

Suitability – Outdoor: Yes
Suitability – Sunlight Resistance: Yes

Flammability, LS0H, Toxicity Testing

IEC Flammability: IEC 60332-1-2, IEC 60332-3-24
IEC 60754-1 – Halogen Amount: Zero
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: 2.5 µS/mm
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: 4.3
IEC 61034-2 – Smoke Density Min. Transmittance: 60%

Related Part Numbers

Variants
Item # Color Put-Up Type Length EAN
3076ELS.07500 Black Reel 500 m 8719605180131
3076ELS.00500 Blue Reel 500 m 8719605005397
3076ELS.001000 Blue Reel 1,000 m 8719605005380
3076ELS.03320 Orange Reel 320 m 8719605005441
3076ELS.03500 Orange Reel 500 m 8719605005458
3076ELS.031000 Orange Reel 1,000 m 8719605005434
3076ELS.051000 Orange Reel 1,000 m 8719605005465
3076ELS.031150 Orange Reel 1,150 m 8719605179968
3076ELS.02500 Yellow Reel 500 m 8719605005427
3076ELS.021000 Yellow Reel 1,000 m 8719605005403
3076ELS.021100 Yellow Reel 1,100 m 8719605005410

History

Update and Revision: Revision Number: 0.233 Revision Date: 02-20-2024