Product Overview
| Product Category: | Fiber Distribution Cable |
| Suitable Applications: | Extended Distance Horizontal & Backbone Data/Telco Network, Noisy Environment, Indoor/Outdoor & Wet Locations, Oil Res 1 /2 |
Fiber Specifications
| Fiber Type: | OM1 |
| Fiber Core Diameter: | 62.5/120 µm |
| Fiber Diameter: | 250 µm |
| Buffer Material: | PVC – Polyvinyl Chloride |
| Fiber Count: | 12 |
| Fiber Color Coding: | TIA-598-D |
Cable Construction
| Number of Active Subunits: | 1 |
| Fibers Per Subunit: | 12 |
Outer Jacket Specifications
| Strength Member: | Waterblocking Aramid Yarns |
| Jacket Material: | CPE – Chlorinated Polyethylene |
| Nom. Diameter: | 0.260 in (6.6 mm) |
| Number of Ripcords: | 1 |
| Wavelength | 850 nm | 1300 nm |
|---|---|---|
| Max. Attenuation | 3.5 dB/km | 1.25 dB/km |
| 1 Gigabit Ethernet Performance | 300 m | 550 m |
| 10 Gigabit Ethernet Performance | 33 m | – |
| Min. Restricted Mode Launch | 220 MHz.km | – |
| Min. Overfilled Launch (OFL) Bandwidth | 200 MHz.km | 500 MHz.km |
Mechanical Characteristics
| Min. Bend Radius During Installation: | 15x Cable OD |
| Min. Bend Radius During Operation: | 10x Cable OD |
| Max. Tensile Strength During Installation: | 660 N (150 lbf) |
| Max. Tensile Strength During Operation: | 200 N (45 lbf) |
| Crush Resistance: | 220 N/cm |
| Bulk Cable Weight: | 27 lbs/kft (40 kg/km) |
Temperature Range
| Installation Temperature Range: | -10°C to +60°C |
| Operating Temperature Range: | -50°C to +70°C |
| Storage Temperature Range: | -50°C to +70°C |
Standards and Compliance
| Environmental Suitability: | Indoor/Outdoor, Sunlight Resistance, Oil Resistance |
| Sustainability: | CA Prop 65 |
| Flammability / Reaction to Fire: | OFNR, FT4 |
| ICEA Compliance: | S-104-696 |
History
| Update and Revision: | Revision Number: 0.14 Revision Date: 11-14-2022 |
Part Numbers
| Item # | Color | Putup Type | UPC |
|---|---|---|---|
| TU-1D9-012-RN2N | Black | Cut to Length | 612825485278 |