NOAD12MA008BKAA – Universal OFC MLT: Steel Central strength member, Gel filling loose tubes(4f/T), Gel filled core, WB Tape + LSZH Inner Jacket (black) + CST + LSZH Outer Jacket (black) 8F OS2


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: For outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and /or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and /or tubes. Suitable for Direct Burial.

Fiber Specifications

Fiber Type: OS2, G.652.D
Fiber Core Diameter: 9 µm
Fiber Diameter: 125 µm
Buffer Material: PBT Polybutylene Terephthalate
Fiber Count: 8
Fiber Color Coding: TIA-598-D

Cable Construction

Number of Active Subunits: 2
Number of Fillers: 4
Fibers Per Subunit: 4
Subunit Waterblocking: Gel Filled
Subunit Color: Blue, Orange
Central Strength Member: Steel Rod

Inner Jacket Specifications

Material: LSZH – Low Smoke Zero Halogen (Flame Retardant)
Color: Black
Number of Ripcords: 1

Armor Specifications

Armor Type and Material: CST – Corrugated Steel Tape

Outer Jacket Specifications

Jacket Material: LSZH – Low Smoke Zero Halogen (Flame Retardant)
Nom. Diameter: 13.2 mm (0.520 in)
Color: Black
Number of Ripcords: 1
Optical Characteristics
Wavelength 1310 nm 1550 nm
Max. Attenuation 0.36 dB/km 0.22 dB/km
Mode Field Diameter 9.2 µm 10.4 µm

Mechanical Characteristics

Min. Bend Radius During Installation: 330 mm
Min. Bend Radius During Operation: 165 mm
Max. Tensile Strength During Installation: 3000 N (670 lbf)
Max. Tensile Strength During Operation: 1000 N (220 lbf)
Crush Resistance: 3000N/100mm
Bulk Cable Weight: 246 kg/km (165 lbs/1000ft)

Temperature Range

Operating Temperature Range: – 40°C to +70°C
Storage Temperature Range: – 40°C to +70°C

Standards and Compliance

Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, UV Resistance, Burial
Flammability / Reaction to Fire: IEC 60332-3-24
ISO/IEC Compliance: IEC 60793-1-1IEC 60794-1-1
European Directive Compliance: EU Directive 2011/65/EU (RoHS 2)

History