Product Overview
| Suitable Applications: | Horizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base – T (Gigabit Ethernet), 100 Base – T, 10 Base – T, FDDI, ATM |
Construction Details
| Element | Size | Stranding | Material | No. of Pairs | No. of Elements |
|---|---|---|---|---|---|
| Individual Pair | 24 AWG | Solid | BC – Bare Copper | 8 | 16 |
| Element | Material | Nom. Insulation Diameter | Color Code |
|---|---|---|---|
| Individual Pair | PE – Polyethylene | 1 mm (0.039 in) | White/Blue & Blue, White/Orange & Orange, White/Green & Green, White/Brown & Brown |
| Description |
|---|
| 4 pairs twisted together |
| Material | Nom. Diameter |
|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 5.5 mm (0.22 in) |
| Table Notes: | Figure 8 construction |
| Overall Cable Diameter (Nominal): | 5.5 mm (0.22 in) |
Electrical Characteristics
| Max. Conductor DCR | Max. Mutual Capacitance | Max. Capacitance Unbalance | Nom. Characteristic Impedance |
|---|---|---|---|
| 94 Ohm/km | 56 pF/m (17 pF/ft) | 160 pF/100m | 100 Ohm |
| Max. Delay Skew | Nom. Velocity of Prop. |
|---|---|
| 45 ns/100m |
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 dB/100m | 75.3 | 73.3 | 73.3 | 71.3 | 70.8 | 67.8 | 20 | 40 | 35 |
| 4 | 3.7 dB/100m | 66.3 | 64.3 | 62.6 | 60.6 | 58.8 | 55.8 | 23 | 40 | 23 |
| 10 | 5.8 dB/100m | 61.8 | 59.8 | 56 | 54 | 50.8 | 47.8 | 25 | 40 | 15 |
| 16 | 7.4 dB/100m | 58.6 | 56.6 | 51.2 | 49.2 | 46.7 | 43.7 | 25 | 38 | 10.9 |
| 31.2 | 10.4 dB/100m | 54 | 52 | 43.6 | 41.6 | 40.9 | 37.9 | 23.6 | 35.1 | 5.1 |
| 62.5 | 15 dB/100m | 49.1 | 47.1 | 34.1 | 32.1 | 34.9 | 31.9 | 21.5 | 32 | |
| 100 | 19.3 dB/100m | 45.8 | 43.8 | 26.5 | 24.5 | 30.8 | 27.8 | 20.8 | 30 | |
| 155 | 24.5 dB/100m | 42.7 | 40.7 | 18.2 | 16.2 | 27 | 24 | 19.5 | 29 | |
| 200 | 28.3 dB/100m | 40.9 | 38.9 | 12.6 | 10.6 | 24.8 | 21.8 | 18.7 | 27 | |
| 250 | 32.1 dB/100m | 39.3 | 37.3 | 7.2 | 5.2 | 22.8 | 19.8 | 18 | 26 | |
| 300 | 35.6 dB/100m | 38.1 | 36.1 | 2.5 | 21.3 | 18.3 | 17.5 | |||
| 350 | 38.9 dB/100m | 37.1 | 35.1 | 19.9 | 16.9 | 17 | ||||
| 450 | 45 dB/100m | 35.5 | 33.5 | 17.7 | 14.7 | 16.2 |
| Table Notes: | Limits above 300 MHz are for information only. Reference standard: IEC 61156-5 |
| Voltage Rating |
|---|
| 72 V DC |
Mechanical Characteristics
| Operating | Installation |
|---|---|
| -30°C to +60°C | 0°C To +50°C |
| Stationary Min. | Installation Min. |
|---|---|
| 23 mm (0.91 in) | 46 mm |
| Max. Pull Tension: | 130 N (29 lbf) |
| Bulk Cable Weight: | 68 kg/km |
Standards and Compliance
| Environmental Suitability: | Indoor – Euroclass Dca |
| Flammability / Reaction to Fire: | IEC 60332-1-2 |
| CPR Compliance: | CPR Euroclass: Dca-s2,d2,a1 |
| IEEE Compliance: | PoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
| Data Category: | Category 6 |
| TIA/EIA Compliance: | ANSI/TIA 568.2-D |
| ISO/IEC Compliance: | ISO/IEC 11801-1 |
| CENELEC Compliance: | EN 50173-1, Segregation class according EN50174-2 = a |
| European Directive Compliance: | EU CE Mark |
| UK Regulation Compliance: | UKCA Mark |
Product Notes
| Notes: | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. |
History
| Update and Revision: | Revision Number: 0.258 Revision Date: 12-12-2023 |
Part Numbers
| Item # | Color | Putup Type | Length | EAN |
|---|---|---|---|---|
| NN01302.00500 | White | Reel | 500 m | 8719605103642 |












































