Product Overview
| Suitable Applications: | Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines, temperature controllers, control panels, machine cutting tools, auxiliary equipment, motor speed control, production machinery and many more. PUR jacket ensures the cable with excellent abrasion resistance and flex cycles more than 5 million would be ideally applied to drag chain and the frequently moving fields. Shielding would highly enable the cables be qualified with excellent immunity. |
Physical Characteristics (Overall)
| Element | AWG | Stranding | Material | No. of Conductors |
|---|---|---|---|---|
| Conductor(s) | 1 mm² | Class 6 | BC – Bare Copper | 3 |
| Ground | 1 mm² | Class 6 | BC – Bare Copper | 1 |
| Conductor Count: | 4 |
| Material |
|---|
| PVC – Polyvinyl Chloride |
| Color |
|---|
| Black #1 |
| Black #2 |
| Black #3 |
| Green/Yellow |
| Material |
|---|
| PUR – Polyurethane |
| Type | Material |
|---|---|
| Braid | Tinned Copper (TC) |
| Material | Nominal Diameter |
|---|---|
| PUR – Polyurethane | 8.9 mm |
Electrical Characteristics
| Max. Conductor DCR |
|---|
| 19.5 Ohm/km |
| Dielectric Withstand Voltage | Non-UL Description | Non-UL Voltage Rating |
|---|---|---|
| 4000 V | IEC: | 300/500 V |
Temperature Range
| Installation Temperature Range: | -40°C to +80°C |
| Operating Temperature Range: | -5°C to +70°C |
Mechanical Characteristics
| Oil Resistance: | Yes |
| UV Resistance: | Yes |
| Bulk Cable Weight: | 121 kg/km |
| Min. Bend Radius During Installation: | 4 x OD |
| Min. Bend Radius During Operation: | 7.5 x OD |
| Min No. of Drag Chain Cycles: | ? 5,000,000 Cycles ( 1MT Traverse Distance, 20cycles/min, 1.5m/s) ? 200,000 Cycles ( 5MT Traverse Distance, 20cycles/min, 1.5m/s) |
Applicable Environmental and Other Programs
| EU Directive 2011/65/EU (RoHS 2): | Yes |
Suitability
| Suitability – Indoor: | Yes |
| Suitability – Oil Resistance: | Yes |
| Suitability – Outdoor: | Yes |
| Suitability – Sunlight Resistance: | Yes |
Flammability, LS0H, Toxicity Testing
| IEC Flammability: | IEC 60332-1-2 |
| Other Flammability: | DIN VDE 0482-332-1-2, DIN EN 60332-1-2 |
History
| Update and Revision: | Revision Number: 0.16 Revision Date: 04-08-2022 |