Product Overview
| Suitable Applications: | Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas |
Construction Details
| RG Type: | 59 |
| Series Type: | 59 |
| No. of Elements | Size | Stranding | Nom. Diameter | Material |
|---|---|---|---|---|
| 1 | 21 AWG | Solid | 0.8 mm | BC – Bare Copper |
| Material | Nom. Insulation Diameter |
|---|---|
| PE – Polyethylene (Foam) | 3.5 mm (0.14 in) |
| Table Notes: | Gas Injected |
| Layer | Outer Shield Type | Material | Coverage |
|---|---|---|---|
| 1 | Tape | Bi-Laminate (Alum+Poly) | 100% |
| 2 | Braid | Tinned Copper (TC) | 75% |
| 3 | Tape | Bi-Laminate (Alum+Poly) | 100% |
| Material | Nom. Diameter |
|---|---|
| PVC – Polyvinyl Chloride | 5 mm |
Electrical Characteristics
| Regularity of Impedance: | 40 dB |
| Frequency | Min. Return Loss | Min. Structural Return Loss |
|---|---|---|
| 5 – 470 MHz | 20 dB | 20 dB |
| 470 – 1000 MHz | 18 dB | 18 dB |
| 1000 – 2000 MHz | 16 dB | 16 dB |
| 2000-3000 MHz | 15 dB | 15 dB |
| Table Notes: | Max. 3 peak values 4 dB lower than specified |
| Frequency | Nom. Attenuation | Max. Attenuation |
|---|---|---|
| 5 MHz | 1.8 dB/100m | 2.3 dB/100m |
| 50 MHz | 4.7 dB/100m | 5.9 dB/100m |
| 100 MHz | 6.5 dB/100m | 8.1 dB/100m |
| 230 MHz | 9.8 dB/100m | 12.1 dB/100m |
| 400 MHz | 13 dB/100m | 15.9 dB/100m |
| 800 MHz | 18.7 dB/100m | 22.7 dB/100m |
| 862 MHz | 19.5 dB/100m | 23.6 dB/100m |
| 1000 MHz | 21.1 dB/100m | 25.6 dB/100m |
| 1350 MHz | 24.9 dB/100m | 30 dB/100m |
| 1750 MHz | 28.8 dB/100m | 34.5 dB/100m |
| 2150 MHz | 32.3 dB/100m | 38.6 dB/100m |
| 2400 MHz | 34.4 dB/100m | 41 dB/100m |
| 3000 MHz | 39.2 dB/100m | 45.9 dB/100m |
| Table Notes: | Maximum attenuation is 10% higher |
| Max. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance Cond-to-Shield |
Nom. Characteristic Impedance | Nom. Velocity of Prop. |
|---|---|---|---|---|
| 35 Ohm/km (11 Ohm/1000ft) | 13 Ohm/km (4.0 Ohm/1000ft) | 53 pF/m (16 pF/ft) | 75 Ohm | 84% |
| Frequency | Max. Transfer Impedance |
|---|---|
| 5-30 MHz | 2.5 mOhm/m |
| Frequency | Min. Screening Attenuation |
|---|---|
| 30-1000 MHz | 95 |
| 1000-2000 MHz | 85 |
| 2000-3000 MHz | 75 |
| Screening Class: | A+ |
Mechanical Characteristics
| Operating | Storage |
|---|---|
| -30°C To +70°C | -30°C To +70°C |
| Stationary Min. |
|---|
| 25 mm (0.98 in) |
| Bulk Cable Weight: | 29 kg/km |
Standards and Compliance
| Environmental Suitability: | Indoor – Euroclass Eca |
| Flammability / Reaction to Fire: | IEC 60332-1-2 |
| CPR Compliance: | CPR Euroclass: Eca |
| CENELEC Compliance: | EN 50117-1 |
| UK Regulation Compliance: | UKCA Mark |
History
| Update and Revision: | Revision Number: 0.158 Revision Date: 03-30-2023 |