Product Overview
| Suitable Applications: | IBDN System 10GX, TIA Category 6A, 10GBASE-T, Support Power over Ethernet (up to 100W), Cisco UPOE (up to 60W) and Power over HDBase-T (up to 100W) |
Physical Characteristics (Overall)
| AWG | Stranding | Material | No. of Pairs |
|---|---|---|---|
| 24 | Solid | BC – Bare Copper | 4 |
| Material |
|---|
| PO – Polyolefin |
| Material |
|---|
| PVC – Polyvinyl Chloride |
| Material |
|---|
| PVC – Polyvinyl Chloride |
| Overall Nominal Diameter: | 0.85 in |
| Material: | PVC – Polyvinyl Chloride |
| Wiring Scheme: | T568A/B-T568A/B |
| Packaging: | Individually packaged in a box |
Connectors
| Description | Material | Type |
|---|---|---|
| Plug | Polycarbonate | RJ45 |
| Boot | Elastomer | |
| Front Connection | Phosphor Bronze with 50u inch Gold over Nickel Plating | Blades |
| Sleeve | Engineered Polymer Riser Rated |
Electrical Characteristics
| Dielectric Strength: | 1,000 V RMS @ 60 Hz for 1 minute |
| Current Rating: | 1.500 A |
| Insulation Resistance: | 500 M-Ohm Minimum |
| Max Contact Resistance: | 20 mOhm |
| Table Notes: | 100 meter Cable Specifications – * TIA/EIA-568.2-D Category 6 Standard |
| UL Voltage Rating |
|---|
| 300 V RMS |
| Frequency (MHz) | Max. Insertion Loss Belden** (dB) |
Min. Return Loss Belden** (dB) |
Min. PSANEXT TIA* (dB) |
Min. PSANEXT Belden** (dB) |
Min. PSAACRF TIA* (dB) |
Min. PSAACRF Belden** (dB) |
Min. Balanced TCL TIA* (dB) |
Min. Balanced TCL Belden** (dB) |
|---|---|---|---|---|---|---|---|---|
| 1 MHz | 2.4 dB | 20 dB | 67 dB | 87 dB | 67 dB | 75 dB | 40 dB | 48 dB |
| 4 MHz | 4.5 dB | 23 dB | 67 dB | 87 dB | 66.2 dB | 75 dB | 40 dB | 48 dB |
| 8 MHz | 6.3 dB | 24.5 dB | 67 dB | 87 dB | 60.1 dB | 75 dB | 40 dB | 48 dB |
| 10 MHz | 7 dB | 25 dB | 67 dB | 87 dB | 58.2 dB | 75 dB | 40 dB | 48 dB |
| 16 MHz | 8.9 dB | 25 dB | 67 dB | 87 dB | 54.1 dB | 70.9 dB | 38 dB | 46 dB |
| 20 MHz | 10 dB | 25 dB | 67 dB | 87 dB | 52.2 dB | 69 dB | 37 dB | 45 dB |
| 25 MHz | 11.1 dB | 25 dB | 67 dB | 87 dB | 50.2 dB | 67 dB | 36 dB | 44 dB |
| 31.25 MHz | 12.5 dB | 25 dB | 67 dB | 87 dB | 48.3 dB | 65.1 dB | 35.1 dB | 43.1 dB |
| 62.5 MHz | 17.9 dB | 25 dB | 65.6 dB | 85.6 dB | 42.3 dB | 59.1 dB | 32 dB | 40 dB |
| 100 MHz | 22.8 dB | 25 dB | 62.5 dB | 82.5 dB | 38.2 dB | 55 dB | 30 dB | 38 dB |
| 200 MHz | 33 dB | 21 dB | 58 dB | 78 dB | 32.2 dB | 49 dB | 27 dB | 35 dB |
| 250 MHz | 37.2 dB | 20.5 dB | 56.5 dB | 76.5 dB | 30.2 dB | 47 dB | 26 dB | 34 dB |
| 300 MHz | 41 dB | 20.1 dB | 55.3 dB | 75.3 dB | 28.7 dB | 43.8 dB | 25.2 dB | 33.2 dB |
| 400 MHz | 48 dB | 19.5 dB | 53.5 dB | 73.5 dB | 26.2 dB | 38.8 dB | 24 dB | 32 dB |
| 500 MHz | 54.3 dB | 18.4 dB | 52 dB | 72 dB | 24.2 dB | 35 dB | 23 dB | 31 dB |
| 625 MHz | 61.5 dB | 17.4 dB | 65 dB | 31.1 dB |
Temperature Range
| Installation Temperature Range: | -10°C To +60°C |
| Storage Temperature Range: | -40°C To +70°C |
| Operating Temperature Range: | -10°C To +60°C |
Mechanical Characteristics
| Max. Pull Tension: | 11.250 lbs |
| Min Bend Radius (Overall Cable): | 1.040 in |
| Plug /Jack Compatibility: | RJ45 |
| Termination | Connection | Durabilities |
|---|---|---|
| RJ45 | Mated Connection | 750 Cycles |
Standards
| UL Rating: | Riser |
| TIA/EIA Compliance: | Category 6A – TIA-568.2-D ISO/IEC 11801-1 |
| IEEE Compliance: | IEEE 802.3at type 1 and 2 (PoE) up to 30W, IEEE 802.3bt type 3 and 4 (PoE) up to 100W, CISCO (UPOE) up to 60W, Power over HDBaseTTM (POH) up to 100W |
| Other Standards: | ANSI/TIA 1096-A (formerly FCC Part 68-F), IEC 60603-7 |
Applicable Environmental and Other Programs
| Environmental Space: | Indoor |
| EU Directive 2002/95/EC (RoHS): | Yes |
| MII Order #39 (China RoHS): | EUP 50 |
Suitability
| Suitability – Indoor: | Yes |
Flammability, LS0H, Toxicity Testing
| UL voltage rating: | 300 V RMS |
| Safety Listing: | c(UL)us Listed |
Related Part Numbers
| Related Parts: | 10GX RJ45 Couplers, 10GX Coupler Patch Panels |
Product Notes
| Notes: | CA21xyyzzzA06 is subdivided as following CA-21-x-yy-zzz-A-06 where CA stands for performance, 21 stands for jacket type, x stands for termination type, yy stands for color, zzz stands for length, A stands for assembly, and 06 stands for number of cables Use “zzz” part of the code to specify length in feet – 006-100 ft in increments of 1 ft – 105-265 ft in increments of 5 ft. Cable Weight: 0.029 lbs/ft. x 6 cables. Cable with EquiBlock Barrier Technology. |
| Labeling: | Labeled at both ends: Part Number, Serial Number, Termination Scheme, Length, Individual cable identification. Customized Labeling for cable assemblies optional upon request. |
History
| Update and Revision: | Revision Number: 0.18 Revision Date: 02-09-2024 |