| Suitable Applications: | 1 single pair Ethernet up to 600 MHz |
Physical Characteristics (Overall)
| AWG | Stranding | Material | No. of Pairs |
|---|---|---|---|
| 22 | 7×0.25 mm | TC – Tinned Copper | 1 |
| Conductor Count: | 2 |
| Type | Material | Nominal Diameter |
|---|---|---|
| Insulation | XLP, XLPO, XLPE | 2.10 mm |
| Color |
|---|
| Nature |
| Nature & Blue |
| Type | Material | Min. Coverage [%] |
|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | |
| Braid | Tinned Copper (TC) | 80% |
| Material | Nominal Diameter |
|---|---|
| LSZH – Low Smoke Zero Halogen (SHF1) | 6.20 mm |
Construction and Dimensions
| Min Elongation at Breakof Insulation: | 200 % |
| Min Elongation at Breakof InsulAged: | 25 % |
| Min Tensile Strength of Insulation Aged: | 25% |
| Min Tensile Strength at Breakof Insul: | 12.5 MPa |
| Min Elongation at Breakof Jacket: | 120 % |
| Min Tensile Strength of Jacket: | 9.0 MPa |
| Min Tensile Strength of Jacket Aged: | 30 % |
| Min Elongation at Break of Jacket Aged: | 30 % |
Electrical Characteristics
| Max. Conductor DCR | Max. DCR Unbalanced Within Pair [%] |
|---|---|
| 59.4 Ohm/km | 2 % |
| Max. Capacitance Unbalance |
|---|
| 160 pF/100m |
| Dielectric Strength: | 0.7 kVac/1 min |
| Insulation Resistance: | 5000 MOhm*km |
| Insulation Resistance (Cond to Cond): | 5000 MOhm*km |
| Insulation Resistance (Cond to Screen): | 5000 MOhm*km |
| Nominal Characteristic Impedance |
|---|
| 100 Ohm |
| Frequency [MHz] | Max. Delay |
|---|---|
| 4 MHz | 552 ns/100m |
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. RL (Return Loss) [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
|---|---|---|---|---|
| 1 MHz | 3.0 dB/100m | 20 dB | 40 dB | 40 dB |
| 10 MHz | 8.7 dB/100m | 25 dB | 35 dB | 20 dB |
| 20 MHz | 12.3 dB/100m | 25 dB | 30.5 dB | 13.9 dB |
| 600 MHz | 70.6 dB/100m | 15.6 dB | 8.3 dB | 5 dB |
| Coupling Attenuation Class: | Type I |
| Transfer Impedance Class: | Grade 1 |
| Voltage Rating [V] |
|---|
| 300 V |
Temperature Range
| Operating Temperature Range: | -20°C to + 80°C |
Mechanical Characteristics
| Impact Resistance Test: | Test on jacket at (-35 ± 2)°C/16h: No cracks |
| Bending Test: | Test on jacket at -(40±2)°C/16h : No cracks |
| Pressure Test for Jacket: | at 80°C x 4h (IEC 60811-3-1): ? 50% |
| Flexibility Test: | Test on jacket at (121±2)°C x 168h (UL 758): No cracks |
| Deformation Test for Insulation: | At 121°Cx1hx250gf (UL 758) : ? 50% |
| Deformation Test for Jacket: | At 100°Cx1hx2kgf (UL 758) : ? 50% |
| Max Dielectric Shrinkage: | 5 % |
| Dielectric Shrinkage Description: | Shrinkage of Insulation (IEC60811-1-3) |
| Cold Bend Test: | No Crack |
| Heat Stroke Test: | No cracks |
| Heat Stroke Test Description: | Test on jacket at 150°Cx1h (IEC 60811-3-1) |
| Low Temperature Test: | No cracks |
| Low Temperature Test Description: | Test for Insulation and Jacket at -20°Cx4hxØ6mm (IEC60811-1-4) |
| Compatibility Test for Insulation: | at (100±2)°C for 168hrs: ±25% |
| Compatibility Test for Jacket: | at (100±2)°C for 168hrs: ±30% |
| IRM 902 Mineral Oil Resistance Test: | At 70C° x 4hr- Tensile Strength(for Jacket): ? 60% of Original Elongation at break(for Jacket):? 60% of Original |
| UV Resistance 720h per UL1581: | Tensile Strength (Mpa) – 85% of original, Elongation at break (%) – 85% of original |
Standards
| UL AWM Style Compliance: | AWM 21307 |
| Data Category: | SPE 1000 Mbps |
| Other Standards: | IEC 61156-12 NP, UL 758, IEC 60092-376 |
Applicable Environmental and Other Programs
| EU Directive 2002/95/EC (RoHS): | Yes |
Flammability, LS0H, Toxicity Testing
| UL Flammability: | FT 2 |
| IEC Flammability: | IEC 60332-1-2, IEC 60332-3-22 |
| Fluorine Content Test IEC60684-2: | ? 0.1 % |
| IEC 60754-1 – Halogen Amount: | 0.5 % |
| IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 10 µS/mm |
| IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
| IEC 61034-2 – Smoke Density Min. Transmittance: |