BE43802 – Railtuff ® 7, 4PR #24 Str TC, XLPE ins, S/FTP, LSNH Jkt, EN 45545 HL 1-3, ECE R118.03


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: For use in railway applications such as rolling stock, buses or other vehicles, cable meets the requirements of the relevant parts of international railway standards like DIN 5510-2, EN 50153, EN 50155, EN 50305 and EN 45545-2, ECE R118.03

Construction Details

Conductor
Size Stranding Material No. of Pairs No. of Elements
24 AWG 19×36 TC – Tinned Copper 4 8
Insulation
Material Nom. Insulation Diameter Color Code Notes
PO – Polyolefin (Foam) 1.45 mm (0.0571 in) White & Blue, White & Orange, White & Green, White & Brown eBeam Cross-Linked
Table Notes: Insulation OD tolerance +/- 0.05mm
Cable Core
Description
4 pairs twisted together
Inner Shield
Element Shield Type Material
Individual Shielded Pair Tape Bi-Laminate (Alum+Poly)
Table Notes: Aluminium facing outside
Outer Shield
Shield Type Material Coverage
Braid Tinned Copper (TC) 80%
Outer Jacket
Material Nom. Diameter
LSZH – Low Smoke Zero Halogen (Flame Retardant, Thermoset) 8.1 mm (0.32 in)
Table Notes: e-Beamed to Cross-link, cable meets smoke test of LU 1-085. Jacket OD +/- 0.3mm
Overall Cable Diameter (Nominal): 8.1 mm (0.32 in)

Electrical Characteristics

Electricals
Max. Conductor DCR Max. Mutual Capacitance Max. Capacitance Unbalance Nom. Characteristic Impedance
95 Ohm/km 56 pF/m (17 pF/ft) 160 pF/100m 100 Ohm
Delay
Max. Delay Skew Nom. Velocity of Prop.
25 ns/100m 78%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation)
1 2.9 dB/100m
4 5.6 dB/100m
10 8.8 dB/100m
16 11.1 dB/100m
31.2 15.6 dB/100m
62.5 22.3 dB/100m
100 28.5 dB/100m
300 51.3 dB/100m
600 75.1 dB/100m
1000 100.4 dB/100m
Table Notes: Limits below 4MHz are for information only. Values at 1000 MHz are for information only
Transfer Impedance Class: Grade 1
Table Notes: IEC 61156-5
Screening Class: Type I
Table Notes: Coupling attenuation
Voltage
Voltage Rating
300 V

Mechanical Characteristics

Temperature
Operating Installation Storage
-40°C to +90°C -25°C To +50°C -40°C to +90°C
Bend Radius
Stationary Min. Installation Min.
32 mm (1.3 in) 64 mm

Standards and Compliance

Environmental Suitability: Indoor, Oil Resistance
Flammability / Reaction to Fire: IEC 60332-1-2, IEC 60332-2-25, UN ECE R118.03
Data Category: Category 7
ISO/IEC Compliance: ISO/IEC 11801-1
CENELEC Compliance: EN 45545-2, Segregation class according EN50174-2 = d
European Halogen Free Standards: IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
European Directive Compliance: EU CE Mark

History

Update and Revision: Revision Number: 0.230 Revision Date: 03-18-2024

Part Numbers

Variants
Item # Color Putup Type Length EAN
BE43802.00500 Blue Reel 500 m 8719605026576

Select at least 2 products