Product Overview
| Suitable Applications: | RG62A/U Coax 93 Ohm; For data transmission applications |
Physical Characteristics (Overall)
| AWG | Stranding | Material | Nominal Diameter | No. of Conductors |
|---|---|---|---|---|
| 22 | Solid | BCCS – Bare Copper Covered Steel | 0.64 in | 1 |
| Type | Material | Nominal Diameter | Diameter +/- Tolerance |
|---|---|---|---|
| Semi-solid dielectric | PO – Polyolefin | 3.71 mm | 0.13 mm |
| Number | Color |
|---|---|
| Wire 1 | Clear |
| Material | Color | Nominal Diameter | Nominal Wall Thickness |
|---|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | Black | 6.1 mm | 0.89 mm |
| Type | Material | Coverage [%] |
|---|---|---|
| Braid | Bare Copper (BC) | 95% |
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 10.55 mm | 1.3 mm |
Construction and Dimensions
| Type of Armor | Material | Thickness of Armoring Wires | Coverage Percentage |
|---|---|---|---|
| Steel Wire Armoring | Galvanized steel wire | 0.9 mm | Min. 95% |
Electrical Characteristics
| Nominal Conductor DCR | Nominal Outer Shield DCR |
|---|---|
| 135.2 Ohm/km | 9.5 Ohm/km |
| Nom. Capacitance Conductor to Shield |
|---|
| 44.3 pF/m |
| Nominal Inductance |
|---|
| 0.38 µH/m |
| Nominal Characteristic Impedance |
|---|
| 93 Ohm |
| Frequency [MHz] | Nom. Insertion Loss |
|---|---|
| 1 MHz | 0.82 dB/100m |
| 10 MHz | 2.79 dB/100m |
| 50 MHz | 6.23 dB/100m |
| 100 MHz | 8.86 dB/100m |
| 200 MHz | 12.47 dB/100m |
| 400 MHz | 17.39 dB/100m |
| 700 MHz | 23.95 dB/100m |
| 900 MHz | 26.9 dB/100m |
| 1000 MHz | 28.54 dB/100m |
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|---|
| 400 ns/ft | 84% |
| Voltage Rating [V] |
|---|
| 750 V |
Temperature Range
| Installation Temperature Range: | -15°C To +80°C |
| Storage Temperature Range: | -45°C to +80°C |
| Operating Temp Range (Flexible Install): | -15 to +80 °C |
| Operating Temp Range (Fixed Install): | -45 to +80 °C |
Mechanical Characteristics
| Oil Resistance: | IEC 60811-404 |
| Min. Bend Radius During Installation: | 158.25 mm |
Standards
| CENELEC Compliance: | EN 50290-2-20 |
Suitability
| Suitability – Sunlight Resistance: | Yes |
Flammability, LS0H, Toxicity Testing
| IEC Flammability: | IEC 60332-3-24 |
| IEC 60754-1 – Halogen Amount: | Zero |
| IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 2.5 µS/mm |
| IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
| IEC 61034-2 – Smoke Density Min. Transmittance: | 60% |
Related Part Numbers
| Item # | Color | Put-Up Type | Length | EAN |
|---|---|---|---|---|
| 9269LS.00500 | Black | Reel | 500 m | 8719605020390 |
| 9269LS.001000 | Black | Reel | 1,000 m | 8719605020383 |
History