7809A – RF 300 Wireless Coax, #13


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Physical Characteristics (Overall)

Conductor
AWG Stranding Material Nominal Diameter No. of Coax
13 Solid BC – Bare Copper 0.072 in 1
Conductor Count: 1
Insulation
Material Nominal Diameter
PE – Polyethylene (Foam) 0.19 in
Table Notes: Gas Injected
Outer Shield
Type Layer Material Material Trade Name Coverage [%]
Tape 1 Tri-Laminate (Alum+Poly+Alum) Duofoil® 100%
Braid 2 Tinned Copper (TC) 95%
Outer Jacket
Material Nominal Diameter
PE – Polyethylene 0.3 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR Nominal Conductor DCR Conductor Resistance Nominal Outer Shield DCR Outer Conductor DCR
2.1 Ohm/1000ft 2.1 Ohm/1000ft 2.4 Ohm/1000ft 2.4 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Shield
23 pF/ft
Inductance
Nominal Inductance
0.06 µH/ft
Impedance
Nominal Characteristic Impedance
50 Ohm
High Frequency (Nominal/Typical)
Frequency [MHz] Nom. Insertion Loss
5 MHz 0.45 dB/100ft
10 MHz 0.6 dB/100ft
30 MHz 1 dB/100ft
50 MHz 1.3 dB/100ft
150 MHz 2.2 dB/100ft
220 MHz 2.7 dB/100ft
450 MHz 3.9 dB/100ft
900 MHz 5.6 dB/100ft
1500 MHz 7.3 dB/100ft
1800 MHz 8.1 dB/100ft
2000 MHz 8.6 dB/100ft
2500 MHz 9.7 dB/100ft
3000 MHz 10.8 dB/100ft
3500 MHz 11.8 dB/100ft
4500 MHz 13.5 dB/100ft
5800 MHz 15.8 dB/100ft
6000 MHz 16 dB/100ft
Delay
Nominal Delay Nominal Velocity of Propagation (VP) [%]
1.17 ns/ft 86%
Power Rating
Frequency [MHz] Max. Power Rating [W] Nominal Power Rating [W]
30 MHz 2,161 W 2,161 W
50 MHz 1,658 W 1,658 W
150 MHz 928 W 928 W
220 MHz 758 W 758 W
450 MHz 522 W 522 W
900 MHz 367 W 367 W
1,500 MHz 278 W 278 W
2,000 MHz 239 W 253 W
2,500 MHz 212 W 239 W
3,500 MHz 179 W 212 W
4,500 MHz 157 W 194 W
6,000 MHz 135 W 179 W
4,500 MHz 157 W 157 W
5,800 MHz 137 W 137 W
6,000 MHz 135 W 135 W
Voltage
Non-UL Voltage Rating
300 V RMS
VSWR
Frequency [MHz] Max. VSWR
5-6000 MHz 1.25:1

Temperature Range

Non-UL Temp Rating: 80°C
Operating Temperature Range: -40°C To +75°C

Mechanical Characteristics

Bulk Cable Weight: 54 lbs/1000ft
Max. Pull Tension: 135 lbs
Min. Bend Radius/Minor Axis: 3 in

Applicable Environmental and Other Programs

Environmental Space: Indoor (Not Riser or Plenum)
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/11/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: No
MII Order #39 (China RoHS): Yes

Suitability

Suitability – Indoor: Yes

Plenum/Non-Plenum

Plenum (Y/N): No

Related Part Numbers

Variants
Item # Color Put-Up Type Length UPC
7809A 010500 Black Reel 500 ft 612825189749
7809A 0101000 Black Reel 1,000 ft 612825189732
Footnote: C – CRATE REEL PUT-UP.

History

Update and Revision: Revision Number: 0.360 Revision Date: 11-09-2022

Select at least 2 products