70010PU – 4C 22AWG, PO Ins, Double Shielded, TPE inner Jkt, TPU Outer Jkt, PROFINET TYPE R Cable


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: High Flex applications

Physical Characteristics (Overall)

Conductor
AWG Stranding Material No. of Conductors
22 Stranded TC – Tinned Copper 4
Conductor Count: 4
Insulation
Material Nominal Diameter Diameter +/- Tolerance
PO – Polyolefin 1.4 mm 0.2 mm
Bonded-Pair: No
Color Chart
Color
White & Yellow & Blue & Orange
Inner Jacket
Material
TPE – Thermoplastic Elastomer
Cabling
Filler Number of Fillers
Yes 5
Outer Shield
Type Material Coverage [%]
Tape Bi-Laminate (Alum+Poly) 90%
Braid Tinned Copper (TC)
Outer Jacket
Material Nominal Diameter Diameter +/- Tolerance
PUR – Polyurethane 7.1 mm 0.2 mm

Construction and Dimensions

Min Elongation at Breakof Insulation: 150 %
Min Elongation at Breakof InsulAged: 70 %
Min Tensile Strength of Insulation Aged: 70 %
Min Tensile Strength at Breakof Insul: 20.7 MPa
Min Elongation at Breakof Jacket: 100 %
Min Tensile Strength of Jacket: 10.3 MPa
Min Tensile Strength of Jacket Aged: 70 %
Min Elongation at Break of Jacket Aged: 65 %

Electrical Characteristics

Conductor DCR
Max. Conductor DCR
59.4 Ohm/km
Impedance
Nominal Characteristic Impedance
100 Ohm
Delay
Max. Delay Skew
20 ns/100m
Voltage
Voltage Rating [V]
300 V

Temperature Range

Operating Temperature Range: -20°C To +80°C

Mechanical Characteristics

Bending Test: Reverse bending test at bending radius 7D, weight 300 g, Speed 60 cycles/min : ? 1 million
Torsion Test: Min Number of Torsions: 5000000
Torsion Test: Description: Stress : +/- 180°, weight : 300g, s=30 cycles/min, torsion length : 1000 mm
Flexibility Test: At 113°C x 168hrs: No cracking (for Insulation & Jacket)
Deformation Test for Insulation: ?50 %
Deformation Test for Jacket: ?50 %
Cold Bend Test: No Crack
IRM 902 Mineral Oil Resistance Test: At (100°Cx96hrs) – Tensile Strength of Jacket : ? 50% of original and Elongation of jacket : ? 50% of original
Min No. of Drag Chain Cycles: ? 5 million
Drag Chain Parameters: r=15 D, a= 10m/s^2, v= 180m/min, chain length : 5 m

Standards

UL AWM Style Compliance: AWM 20549
ISO/IEC Compliance: ISO/IEC 11801-1, IEC 61156-6
Data Category: Category 5e

Applicable Environmental and Other Programs

Environmental Space: Indoor

Suitability

Suitability – Indoor: Yes
Suitability – Oil Resistance: Yes

Flammability, LS0H, Toxicity Testing

IEC 60754-1 – Halogen Amount: HCl + HBr : According to EN60754-1 :?0.5 %,
HF : According to EN 60684-2 : ?0.1 %

History

Update and Revision: Revision Number: 0.19 Revision Date: 03-18-2024

Select at least 2 products