, , , ,

62T1806 – Inst PVC/PVC, 6 Tri #18 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, TC NPLF 90C Dry 75C Wet


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, …),low voltage digital control (24v, …), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners

Physical Characteristics (Overall)

Conductor
AWG Stranding Material Nominal Diameter
18 7×26 BC – Bare Copper 0.045 in
Conductor Count: 18
Total Number of Triads: 2
Insulation
Material Nominal Diameter
PVC/Nylon – Polyvinyl Chloride + Nylon 0.088 in
Color Chart
Number Color
Triad 1 Black, White and Red Numbered 1
Triad 2 Black, White and Red Numbered 2
Inner Shield
Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire Diameter Drainwire AWG
Tape Bi-Laminate (Alum+Poly) Beldfoil® 100% TC – Tinned Copper 0.029 in 22
Outer Shield
Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire Diameter Drainwire AWG
Tape Bi-Laminate (Alum+Poly) Beldfoil® 100% TC – Tinned Copper 0.029 in 22
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
PVC – Polyvinyl Chloride 0.470 in 0.047 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR
5.86 Ohm/1000ft
Current
Max. Recommended Current [A]
4.8 Amps per Conductor at 30ºC

Temperature Range

UL Temp Rating: 90°C Dry/75°C Wet
Operating Temperature Range: -25°C To +90°C

Mechanical Characteristics

Bulk Cable Weight: 252 lbs/1000ft
Max. Pull Tension: 134 lbs
Min Bend Radius (Overall): 4.75 in

Standards

NEC Articles: Article 336
NEC/(UL) Compliance: NPLF, TC-ER
IEEE Compliance: 1202

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes
CA Prop 65: Yes

Suitability

Suitability – Indoor: Yes
Suitability – Outdoor: Yes
Suitability – Sunlight Resistance: Yes

Flammability, LS0H, Toxicity Testing

CSA/C(UL) Flammability: FT4
UL voltage rating: 600 V RMS (Type TC)

Related Part Numbers

Variants
Item # Put-Up Type
62T1806 0105500 Reel

History

Update and Revision: Revision Number: 0.43 Revision Date: 01-11-2024

Select at least 2 products
to compare