4442FLV – Security & Sound, #20-3pr, BC, LSZH, Shielded, B2ca


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Intercom/PA Systems, Sound/Audio Systems,
Control Systems

Physical Characteristics (Overall)

Conductor
AWG Material No. of Pairs
20 BC – Bare Copper 3
Conductor Count: 6
Insulation
Material Nominal Diameter Diameter +/- Tolerance
LSZH – Low Smoke Zero Halogen (Flame Retardant) 1.60 mm 0.05 mm
Color Chart
Number Color
Pair 1 Black & Red
Pair 2 Black & White
Pair 3 Black & Green
Outer Shield
Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG
Tape Bi-Laminate (Alum+Poly) Beldfoil® 100% TC – Tinned Copper AWG24/7
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness Ripcord
LSZH – Low Smoke Zero Halogen (Flame Retardant) 8.2 mm 1.1 mm Yes
Table Notes: Ripcord provided under sheath

Construction and Dimensions

Cabling
Description
3 pairs twisted

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR Nominal Outer Shield DCR
34 Ohm/km 36 Ohm/km
Capacitance
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield
125 pF/m 224 pF/m
Current
Max. Recommended Current [A]
2.8 Amps per Conductor
Voltage
Voltage Rating [V]
300 V

Temperature Range

Installation Temperature Range: -20°C To +70°C
Storage Temperature Range: -30°C to +70°C
Operating Temperature Range: -20°C To +70°C

Mechanical Characteristics

Max. Pull Tension: 180 N
Min. Bend Radius During Installation: 82 mm
Min Setting Radius: 41 mm

Standards

CPR Euroclass: B2ca-s1,d1,a1

Applicable Environmental and Other Programs

Environmental Space: Indoor – Euroclass B2ca

Flammability, LS0H, Toxicity Testing

IEC Flammability: IEC 60332-1-2
IEC 60754-1 – Halogen Amount: Zero
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: 2.5 µS/mm
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: 4.3
IEC 61034-2 – Smoke Density Min. Transmittance: 60%

Product Notes

Notes: This is a preliminary Technical Design Specification (TDS) which is subject to modification throughout the prototyping phase.
The minimum business quantity to offer is 6km for the first order.
This product will have Gray as standard color and 305mt or 500mt as standard put-ups. Additional options for colors and put-ups are available on special request.
The estimated production lead time for the first order will be similar to the production lead time of 4342ULW plus extra 6-7 weeks.
Please liaise with your Belden representative for confirmation.

History

Update and Revision: Revision Number: 0.10 Revision Date: 03-19-2024

Select at least 2 products