Product Overview
| Suitable Applications: | Intercom/PA Systems, Sound/Audio Systems, Control Systems |
Physical Characteristics (Overall)
| AWG | Stranding | Material | Nominal Diameter | No. of Conductors |
|---|---|---|---|---|
| 18 | 7×26 | BC – Bare Copper | 1.22 mm | 6 |
| Conductor Count: | 6 |
| Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness |
|---|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 1.72 mm | 0.05 mm | 0.25 mm |
| Color |
|---|
| Black |
| Red |
| White |
| Green |
| Brown |
| Blue |
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 7.3 mm | 1 mm |
Electrical Characteristics
| Nominal Conductor DCR |
|---|
| 21.3 Ohm/km |
| Nom. Capacitance Conductor to Conductor |
|---|
| 100 pF/m |
| Voltage Rating [V] |
|---|
| 300 V |
Temperature Range
| Installation Temperature Range: | -20°C To +70°C |
| Storage Temperature Range: | -30°C To +70°C |
Mechanical Characteristics
| Max. Pull Tension: | 240 N |
| Min. Bend Radius During Installation: | 73 mm |
| Min Setting Radius: | 36 mm |
Standards
| CPR Euroclass: | Cca-s1,d1,a1 |
Applicable Environmental and Other Programs
| Environmental Space: | Indoor – Euroclass Cca |
Flammability, LS0H, Toxicity Testing
| IEC Flammability: | IEC 60332-1-2 |
| IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: | 2.5 µS/mm |
| IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: | 4.3 |
| IEC 61034-2 – Smoke Density Min. Transmittance: | 60% |
History
| Update and Revision: | Revision Number: 0.15 Revision Date: 08-24-2023 |