Product Overview
| Suitable Applications: | Intercom/PA Systems, Sound/Audio Systems, Control Systems |
Construction Details
| Size | Stranding | Material |
|---|---|---|
| 18 | 7×26 | BC – Bare Copper |
| Material | Nom. Thickness | Nom. Insulation Diameter |
|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 0.25 mm (0.0098 in) | 1.72 mm (0.0677 in) |
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7×32) TC |
| Material | Nom. Thickness | Nom. Diameter | Ripcord |
|---|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 1.0 mm (0.039 in) | 5.7 mm (0.22 in) | Yes |
| Overall Cable Diameter (Nominal): | 5.70 mm (0.224 in) |
Electrical Characteristics
| Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) |
|---|---|---|
| 21.3 Ohm/km (6.49 Ohm/1000ft) | 158 pF/m (48.2 pF/ft) | 295 pF/m (89.9 pF/ft) |
Mechanical Characteristics
| Operating | Installation | Storage |
|---|---|---|
| -20°C To +70°C | -20°C To +70°C | -30°C To +70°C |
| Installation Min. |
|---|
| 57 mm (2.2 in) |
| Max. Pull Tension: | 90 N (20 lbf) |
Standards and Compliance
| Environmental Suitability: | Indoor – Euroclass Cca, Non-Halogenated |
| Flammability / Reaction to Fire: | IEC 60332-1-2 |
| CPR Compliance: | CPR Euroclass: Cca-s1,d1,a1 |
| CENELEC Compliance: | EN 50290-2-20 |
| European Halogen Free Standards: | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 2.5 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
| European Directive Compliance: | EU Directive 2011/65/EU (RoHS 2) |
History
| Update and Revision: | Revision Number: 0.7 Revision Date: 02-22-2024 |