Product Overview
| Suitable Applications: | harsh environment, factory automation, ControlNet, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications |
Physical Characteristics (Overall)
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|---|---|---|---|
| 14 | Solid | BCCS – Bare Copper Covered Steel | 0.064 in | 1 |
| Conductor Count: | 1 |
| Material | Nominal Diameter |
|---|---|
| FEP – Fluorinated Ethylene Propylene (Foam) | 0.28 in |
| Type | Layer | Material | Material Trade Name | Coverage [%] |
|---|---|---|---|---|
| Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| Braid | 2 | Aluminum | 60% | |
| Tape | 3 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| Braid | 4 | Aluminum | 40% |
| Material | Nominal Diameter |
|---|---|
| PVDF – Polyvinylidene Fluoride | 0.387 in |
Electrical Characteristics
| Nominal Conductor DCR | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|---|---|
| 11 Ohm/1000ft | 3.9 Ohm/1000ft | 3.9 Ohm/1000ft |
| Nom. Capacitance Conductor to Shield |
|---|
| 16.5 pF/ft |
| Nominal Inductance |
|---|
| 0.097 µH/ft |
| Nominal Characteristic Impedance | Nominal Characteristic Tolerance |
|---|---|
| 100 Ohm | ± 3 Ohm |
| Frequency [MHz] | Nom. Insertion Loss |
|---|---|
| 1 MHz | 0.17 dB/100ft |
| 2 MHz | 0.22 dB/100ft |
| 5 MHz | 0.28 dB/100ft |
| 10 MHz | 0.4 dB/100ft |
| 20 MHz | 0.6 dB/100ft |
| 50 MHz | 1.2 dB/100ft |
| 100 MHz | 1.7 dB/100ft |
| 200 MHz | 2.5 dB/100ft |
| 300 MHz | 3.04 dB/100ft |
| 400 MHz | 3.5 dB/100ft |
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|---|
| 1.2 ns/ft | 82% |
| f/B | %PDD/100M (5MB) |
|---|---|
| 0.5 | -0.6 |
| 1 | -0.46 |
| 1.5 | 0 |
| 2 | 0.17 |
| 2.5 | 0.3 |
| Frequency [MHz] | Min. SRL (Structural Return Loss) |
|---|---|
| 1 MHz | 20 dB |
| 2 MHz | |
| 5 MHz | |
| 10 MHz | |
| 20 MHz | |
| 50 MHz | |
| 100 MHz | |
| 200 MHz | |
| 300 MHz | |
| 400 MHz |
| UL Voltage Rating |
|---|
| 300 V RMS |
| Electrical Characteristics Notes: | Tilt 5 to 10 MHz: .42 dB/100 M |
| Other Electrical Characteristic 2: | Tilt 10 to 20 MHz: .58 dB/100 M |
| Other Electrical Characteristic 3: | SLR Min. 20dB (5MHz – 50MHz) |
Temperature Range
| UL Temp Rating: | 150°C |
| Operating Temperature Range: | -20°C To +150°C |
Mechanical Characteristics
| Bulk Cable Weight: | 68 lbs/1000ft |
| Max. Pull Tension: | 309 lbs |
| Min. Bend Radius/Minor Axis: | 4 in |
Standards
| NEC Articles: | Article 800 |
| NEC/(UL) Compliance: | CMP |
| CEC/C(UL) Compliance: | CMP |
| RG Type: | 11 |
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2011/65/EU (RoHS 2): | Yes |
| EU Directive 2012/19/EU (WEEE): | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment): | Yes |
| EU Directive Compliance: | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS): | Yes |
Suitability
| Suitability – Burial: | Yes |
| Suitability – Outdoor: | Yes |
Flammability, LS0H, Toxicity Testing
| UL Flammability: | NFPA 262 |
| CSA Flammability: | FT6 |
| UL voltage rating: | 300 V RMS |
Plenum/Non-Plenum
| Plenum (Y/N): | Yes |
Related Part Numbers
| Non-Plenum Number: | 3094A |
Product Notes
| Notes: | Sweep tested 5 to 400 MHz. Tap marks every 2.6 meters to aid users in installation. |
History
| Update and Revision: | Revision Number: 0.304 Revision Date: 11-16-2023 |