Product Overview
| Suitable Applications: | harsh environment, outdoors, data transmission applications such as Profibus DP or PA, Instrumentation and computer cable, etc. exposure to temperature extremes, humidity/moisture, dust, and oil. |
Construction Details
| Element | No. of Elements | Size | Stranding | Material |
|---|---|---|---|---|
| Pair(s) | 1 | 22 AWG | Solid | BC – Bare Copper |
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
|---|---|---|---|---|---|
| Pair(s) | PE – Polyethylene (Foam) | 0.035 in (0.89 mm) | 0.099 in (2.5 mm) | Red & Green | Flame Retardant, Foam w/ skin |
| Shield Type | Material | Coverage |
|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% |
| Braid | Tinned Copper (TC) | 65% |
| Material | Nom. Thickness | Nom. Diameter |
|---|---|---|
| PVC – Polyvinyl Chloride | 0.043 in (1.1 mm) | 0.315 in (8.00 mm) |
| Table Notes: | Jacket OD +/- 0.010 |
| Overall Cable Diameter (Nominal): | 0.315 in (8.00 mm) |
Electrical Characteristics
| Element | Nom. Conductor DCR | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|---|---|---|---|
| Pair(s) | 18.9 Ohm/1000ft | 150 Ohm | 78% | 2.3 Amps per Conductor at 25ºC |
| Nom. Outer Shield DCR: | 5.2 Ohm/1000ft (17 Ohm/km) |
| Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
|---|---|---|
| Pair(s) | 0.2 | 0.27 dB/100ft |
| 4 | 0.67 dB/100ft | |
| 16 | 1.37 dB/100ft |
| Frequency [MHz] | Max. Insertion Loss (Attenuation) |
|---|---|
| 0.2 | 1.1 dB/100m |
| 4 | 2.65 dB/100m |
| 16 | 5.4 dB/100m |
| UL Voltage Rating |
|---|
| 600 V (CMG, PLTC), 300 V (AWM 20201) |
Mechanical Characteristics
| UL Temperature | Operating |
|---|---|
| 75°C | -30°C to +75°C |
| Stationary Min. | Installation Min. |
|---|---|
| 2.4 in (61 mm) | 2.4 in (61 mm) |
| Max. Pull Tension: | 50 lbs (23 kg) |
| Bulk Cable Weight: | 52 lbs/1000ft |
Standards and Compliance
| Environmental Suitability: | Indoor, Outdoor, Sunlight Resistance |
| Flammability / Reaction to Fire: | UL 1685 FT4 Loading, FT4, IEEE 1202, IEC 60332-1-2 |
| CPR Compliance: | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| NEC / UL Compliance: | Article 725, Article 800, CM, CMX-Outdoor, PLTC, ITC |
| AWM Compliance: | AWM 20201 |
| CEC / C(UL) Compliance: | CMG |
| European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance: | UKCA Mark |
Product Notes
| Notes: | Siemens Sinec L2 Cable. For CPE jacketed version order Part No. YR45047. For LSZH (FRNC) jacketed version, order Part No. 3079T or YR44731. |
History
| Update and Revision: | Revision Number: 0.529 Revision Date: 02-15-2024 |
Part Numbers
| Item # | Color | Putup Type | Length | UPC | Footnote |
|---|---|---|---|---|---|
| 3079A 0601000 | Chrome | Reel | 1,000 ft | 612825140382 | C |
| 3079A 0602000 | Chrome | Reel | 2,000 ft | 612825140399 | C |
| 3079A 0071000 | Violet | Reel | 1,000 ft | 612825140344 | C |
| 3079A 0072000 | Violet | Reel | 2,000 ft | 612825140351 | C |
| 3079A 0075000 | Violet | Reel | 5,000 ft | 612825140375 |