Product Overview
| Suitable Applications: | Electronics |
Construction Details
| Element | No. of Elements | Size | Stranding | Material |
|---|---|---|---|---|
| Conductor(s) | 3 | 18 AWG | 16×30 | TC – Tinned Copper |
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Conductor(s) | PE – Polyethylene | 0.016 in (0.41 mm) | 0.079 in (2.0 mm) | Black, White, Red |
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7×30) TC |
| Material | Nom. Thickness | Nom. Diameter |
|---|---|---|
| PVC – Polyvinyl Chloride | 0.025 in (0.64 mm) | 0.224 in (5.69 mm) |
| Overall Cable Diameter (Nominal): | 0.224 in (5.69 mm) |
Electrical Characteristics
| Element | Nom. Conductor DCR | Max. Current |
|---|---|---|
| Conductor(s) | 7.06 Ohm/1000ft | 13 Amps per Conductor at 30ºC |
| UL Voltage Rating |
|---|
| 300 V |
Mechanical Characteristics
| UL Temperature | Operating |
|---|---|
| 75°C | -20°C To +75°C |
| Stationary Min. | Installation Min. |
|---|---|
| 2.24 in (56.9 mm) | 2.24 in (56.9 mm) |
| Max. Pull Tension: | 71.5 lbs (32.4 kg) |
| Bulk Cable Weight: | 30 lbs/1000ft |
Standards and Compliance
| Environmental Suitability: | Indoor, Indoor |
| Flammability / Reaction to Fire: | UL 1685 UL Loading, FT4 |
| NEC / UL Compliance: | Article 800, CM |
| AWM Compliance: | AWM 2093 |
| CEC / C(UL) Compliance: | HLABCD, ACIC |
History
| Update and Revision: | Revision Number: 0.38 Revision Date: 11-30-2023 |