1633VHC – DNV GL, Shipboard, Category 5e Cable, 4 Pair, SF/UTP, LSZH Indoor CPR Eca 60332-3-25


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Horizontal and building backbone cable; Support current and future Category 5e applications, such as: 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, FDDI, ATM
Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Construction Details

Conductor
Element Size Stranding Material No. of Pairs No. of Elements
Individual Pair 24 AWG Solid BC – Bare Copper 4 8
Insulation
Element Material Nom. Insulation Diameter Color Code
Individual Pair PE – Polyethylene 1.05 mm (0.0413 in) White/Blue & Blue, White/Green & Green, White/Orange & Orange, White/Brown & Brown
Cable Core
Description
4 pairs twisted together covered with a polyester foil
Outer Shield
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 26 AWG (Solid) TC
Braid Tinned Copper (TC) 40%
Table Notes: Aluminum facing outside in contact with drain wire
Outer Jacket
Material Nom. Diameter
LSZH – Low Smoke Zero Halogen (Flame Retardant) 6.6 mm (0.26 in)
Overall Cable Diameter (Nominal): 6.6 mm (0.26 in)

Electrical Characteristics

Electricals
Max. Conductor DCR Max. Mutual Capacitance Max. Capacitance Unbalance Nom. Characteristic Impedance
95 Ohm/km 56 pF/m (17 pF/ft) 160 pF/100m 100 Ohm
Delay
Max. Delay Skew Nom. Velocity of Prop.
45 ns/100m 69%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Min. TCL [dB] Min. ELTCTL [dB]
1 2.1 dB/100m 65.3 62.3 63.2 60.2 64 61 20 40 35
4 4 dB/100m 56.3 53.3 52.2 49.2 52 49 23 34 23
10 6.3 dB/100m 50.3 47.3 43.8 40.8 44 41 25 30 15
16 8 dB/100m 47.2 44.2 39 36 39.9 36.9 25 28 10.9
20 9 dB/100m 45.8 42.8 36.5 33.5 38 35 25 25.1 9
31.25 11.4 dB/100m 43.1 40.1 31.7 28.7 34.5 31.5 23.8 22 5.5
62.5 16.5 dB/100m 38.4 35.4 21.4 18.4 28.1 25.1 21.5 20
100 21.3 dB/100m 35.3 32.3 13.3 10.3 24 21 20.1 19
Table Notes: Limits below 4 MHz are for information only.
Reference standard: IEC 61156-5
Transfer Impedance
Frequency Max. Transfer Impedance
1 Mhz Max. 50 mOhm/m
10 Mhz Max. 100 mOhm/m
30 Mhz Max. 200 mOhm/m
100 Mhz Max. 1000 mOhm/m
Transfer Impedance Class: Grade 2
Screening Class: Type II
Table Notes: Coupling Attenuation
Voltage
Voltage Rating
72 V DC

Mechanical Characteristics

Temperature
Operating Installation
-30°C to +60°C 0°C To +50°C
Bend Radius
Stationary Min. Installation Min.
48 mm (1.9 in) 48 mm
Max. Pull Tension: 80 N (18 lbf)
Bulk Cable Weight: 43 kg/km

Standards and Compliance

Environmental Suitability: Indoor – Euroclass Eca
Flammability / Reaction to Fire: IEC 60332-3-25
CPR Compliance: CPR Euroclass: Eca
IEEE Compliance: PoE: IEEE 802.3bt Type 1, Type 2, Type 3
Data Category: Category 5e
TIA/EIA Compliance: ANSI/TIA 568.2-D
Third Party Performance Verification: DNV GL certification
ISO/IEC Compliance: ISO/IEC 11801-1
CENELEC Compliance: EN 50173-1, Segregation class according EN50174-2 = c
European Halogen Free Standards: IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 2.5 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
European Directive Compliance: EU CE Mark
UK Regulation Compliance: UKCA Mark

Product Notes

Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system.

History

Update and Revision: Revision Number: 0.102 Revision Date: 12-12-2023

Part Numbers

Variants
Item # Color Putup Type Length EAN
1633VHC.06500 Blue Reel 500 m 8719605180414