89207 – 100? Twinax, 1 Pr #20 Str-1c TC/1c BC, FEP ins, FEP Inner Jkt, Duofoil®+TC Braid, FEP Jkt, CMP


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Computer, Instrumentation

Construction Details

Conductor
Size Stranding Nom. Diameter Material
20 AWG 7×28 0.036 in TC – Tinned Copper
20 AWG 7×28 0.036 in BC – Bare Copper
Insulation
Material Nom. Insulation Diameter Color Code Notes
FEP – Fluorinated Ethylene Propylene 0.072 in (1.8 mm) Clear FEP on both conductors
FEP – Fluorinated Ethylene Propylene 0.201 in (5.11 mm) Clear FEP over pair
Outer Shield
Layer Outer Shield Type Material Material Trade Name Coverage
1 Tape Tri-Laminate (Alum+Poly+Alum) Duofoil® 100%
2 Braid Tinned Copper (TC) 85%
Outer Jacket
Material Nom. Diameter
FEP – Fluorinated Ethylene Propylene 0.259 in (6.58 mm)
Overall Cable Diameter (Nominal): 0.259 in (6.58 mm)

Electrical Characteristics

Attenuation
Frequency Nom. Attenuation
1 MHz 0.30 dB/100m
10 MHz 1.20 dB/100m
50 MHz 2.80 dB/100m
100 MHz 4.10 dB/100m
200 MHz 6.40 dB/100m
300 MHz 8.40 dB/100m
400 MHz 10.20 dB/100m
Electricals
Nom. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance Cond-to-Cond (Mutual) Nom. Capacitance
Cond-to-Shield
Nom. Characteristic Impedance Nom. Velocity of Prop.
9.5 Ohm/1000ft 2.5 Ohm/1000ft (8.2 Ohm/km) 14.0 pF/ft (45.9 pF/m) 23.0 pF/ft (75.5 pF/m) 100 Ohm 70%
Voltage
UL Voltage Rating
300 V (CMP)

Mechanical Characteristics

Temperature
UL Temperature Operating
200°C -70°C to +200°C
Bend Radius
Installation Min.
3.0 in (76 mm)
Max. Pull Tension: 88 lbs (40 kg)
Bulk Cable Weight: 52 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor – Plenum, Indoor
Sustainability: CA Prop 65
Flammability / Reaction to Fire: NFPA 262
CPR Compliance: CPR Euroclass: Eca
NEC / UL Compliance: CMP
CEC / C(UL) Compliance: CMP
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation Compliance: UKCA Mark
APAC Compliance: China RoHS II (GB/T 26572-2011)
Non-Plenum Number: 9207

History

Update and Revision: Revision Number: 0.490 Revision Date: 02-15-2024

Part Numbers

Variants
Item # Color Putup Type Length UPC Footnote
89207 010100 Black Reel 100 ft 612825220756 C
89207 010500 Black Reel 500 ft 612825220770 C
89207 0101000 Black Reel 1,000 ft 612825220763 C

Select at least 2 products