29541 – VFD 300% Gnd, 3C+G #4 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd w/-3#10 TC Drains, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 2000V Flexible Motor Supply Cable WTTC


Call for Price

This product requires special shipping arrangements. Please Use the "ADD TO QUOTE BUTTON" or call us at (866) 650-3282 for more information.

Compare

Product Overview

Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements

Construction Details

Conductor
Element No. of Elements Size Stranding Material
Conductor(s) 3 4 AWG 7x19x25 TC – Tinned Copper
Ground 1 4 AWG 7x19x25 TC – Tinned Copper
Insulation
Element Material Nom. Thickness Color Code
Conductor(s) XLPE – Cross-Linked Polyethylene (Thermoset) 0.071 in (1.8 mm) Black and Numbered
Ground XLPE – Cross-Linked Polyethylene (Thermoset) 0.071 in (1.8 mm) Green/Yellow Stripe
Outer Shield
Shield Type Material Coverage
Tape Tri-Laminate (Alum+Poly+Alum) 100%
Braid Tinned Copper (TC) 85%
Outer Jacket
Material Nom. Thickness Nom. Diameter Ripcord
PVC – Polyvinyl Chloride 0.095 in (2.4 mm) 1.205 in (30.61 mm) Yes
Overall Cable Diameter (Nominal): 1.205 in (30.61 mm)

Electrical Characteristics

Electricals
Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Other (Conds + Shield) Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
Conductor(s) 0.239 Ohm/1000ft (0.784 Ohm/km) 21 pF/ft (69 pF/m) 38 pF/ft (120 pF/m) 90 Ohm 55% 95 Amps per Conductor at 30ºC
Voltage
UL Voltage Rating
2000 V (TC, C(UL) TC), 1000 V (WTTC, UL Flexible Motor Supply Cable, CSA AWM I/II A/B)

Mechanical Characteristics

Temperature
UL Temperature Operating
90°C Dry, 90°C Wet -40°C To +90°C
Bend Radius
Stationary Min. Installation Min.
14.5 in (368 mm) 14.5 in (368 mm)
Max. Pull Tension: 2156 lbs (977.9 kg)
Bulk Cable Weight: 1133 lbs/1000ft (1686 kg/km)

Standards and Compliance

Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
Sustainability: CA Prop 65
Flammability / Reaction to Fire: UL1685 UL Loading, FT4, 1202, 383 Vertical Tray Flame Test (70,000 BTU)
NEC / UL Compliance: Article 336, TC-ER, WTTC, RHW-2, UL Flexible Motor Supply Cable
AWM Compliance: I/II A/B
CEC / C(UL) Compliance: CIC, TC
ICEA Compliance: S-95-658
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC Compliance: China RoHS II (GB/T 26572-2011)
Other Standard Compliance(s): P-07-KA070003-MSHA

History

Update and Revision: Revision Number: 0.480 Revision Date: 12-22-2023

Part Numbers

Variants
Item # Color Putup Type Length UPC
29541 0101000 Black Reel 1,000 ft 612825138495
29541 0103000 Black Reel 3,000 ft 612825138501