Product Overview
| Suitable Applications: | direct burial applications; low voltage analog signals (4-20ma, 0-10v, …); low voltage control (24v, ); line level audio; voice communications |
Construction Details
| Element | No. of Elements | Size | Stranding | Material |
|---|---|---|---|---|
| Conductor(s) | 2 | 20 AWG | Solid | TC – Tinned Copper |
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Conductor(s) | PP – Polypropylene | 0.013 in (0.33 mm) | 0.058 in (1.5 mm) | White, Black |
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (Solid) TC |
| Material | Nom. Thickness | Nom. Diameter |
|---|---|---|
| PE – Polyethylene | 0.035 in (0.89 mm) | 0.19 in |
| Table Notes: | HDPE |
| Overall Cable Diameter (Nominal): | 0.19 in |
Electrical Characteristics
| Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Max. Current |
|---|---|---|---|---|
| 18.1 Ohm/1000ft | 31.6 pF/ft (104 pF/m) | 42 pF/ft (140 pF/m) | 54 Ohm | 3.9 Amps per Conductor at 25ºC |
| Voltage Rating |
|---|
| 350 V |
Mechanical Characteristics
| Operating |
|---|
| -40°C To +80°C |
| Stationary Min. | Installation Min. |
|---|---|
| 1.9 in (48 mm) | 1.9 in |
| Max. Pull Tension: | 37.8 lbs (17.1 kg) |
| Bulk Cable Weight: | 18 lbs/1000ft |
Standards and Compliance
| CPR Compliance: | CPR Euroclass: Fca |
| European Directive Compliance: | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance: | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision: | Revision Number: 0.409 Revision Date: 02-15-2024 |
Part Numbers
| Item # | Color | UPC | Footnote |
|---|---|---|---|
| 9802 0101000 | Black | 612825258711 | C |
| 9802 010500 | Black | 612825258728 |