Physical Characteristics (Overall)
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|---|---|---|---|
| 23 | Solid | BCCS – Bare Copper Covered Steel | 0.023 in | 1 |
| Conductor Count: | 1 |
| Material | Nominal Diameter |
|---|---|
| PE – Polyethylene | 0.146 in |
| Type | Material | Coverage [%] |
|---|---|---|
| Braid | Bare Copper (BC) | 95% |
| Material | Nominal Diameter |
|---|---|
| PVC – Polyvinyl Chloride (Non-Contaminating) | 0.241 in |
Electrical Characteristics
| Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|---|---|---|
| 49 Ohm/1000ft | 49 Ohm/1000ft | 2.6 Ohm/1000ft | 2.6 Ohm/1000ft |
| Nom. Capacitance Conductor to Shield |
|---|
| 20.5 pF/ft |
| Nominal Inductance |
|---|
| 0.115 µH/ft |
| Nominal Characteristic Impedance |
|---|
| 75 Ohm |
| Frequency [MHz] | Nom. Insertion Loss |
|---|---|
| 1 MHz | 0.6 dB/100ft |
| 10 MHz | 1.1 dB/100ft |
| 50 MHz | 2.4 dB/100ft |
| 100 MHz | 3.4 dB/100ft |
| 200 MHz | 4.9 dB/100ft |
| 400 MHz | 7 dB/100ft |
| 700 MHz | 9.7 dB/100ft |
| 900 MHz | 11.1 dB/100ft |
| 1000 MHz | 12 dB/100ft |
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|---|
| 1.54 ns/ft | 66% |
| Non-UL Voltage Rating | UL Voltage Rating |
|---|---|
| 1700 V RMS | 150 V RMS |
Temperature Range
| Non-UL Temp Rating: | 60°C |
| Operating Temperature Range: | -40°C To +60°C |
Mechanical Characteristics
| Bulk Cable Weight: | 36 lbs/1000ft |
| Max. Pull Tension: | 78 lbs |
| Min. Bend Radius/Minor Axis: | 2.5 in |
Standards
| NEC/(UL) Compliance: | CMX |
| CEC/C(UL) Compliance: | CMX |
| UL AWM Style Compliance: | AWM 1354 (30 V 60°C) |
| CPR Euroclass: | Eca |
| RG Type: | 59B |
| Series Type: | 59 |
| Military Compliance: | Mil-C-17D |
Applicable Environmental and Other Programs
| Environmental Space: | Indoor/Outdoor |
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2003/11/EC (BFR): | Yes |
| EU Directive 2011/65/EU (RoHS 2): | Yes |
| EU Directive 2012/19/EU (WEEE): | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment): | Yes |
| EU Directive Compliance: | EU Directive 2003/11/EC (BFR) |
| EU CE Mark: | Yes |
| MII Order #39 (China RoHS): | Yes |
Suitability
| Suitability – Indoor: | Yes |
| Suitability – Outdoor: | Yes |
Flammability, LS0H, Toxicity Testing
| UL Flammability: | VW-1 |
| IEC Flammability: | IEC 60332-1-2 |
| UL voltage rating: | 150 V RMS |
Plenum/Non-Plenum
| Plenum (Y/N): | No |
Related Part Numbers
| Item # | Color | Put-Up Type | Length | UPC |
|---|---|---|---|---|
| 8263 010U500 | Black | UnReel | 500 ft | 612825197515 |
| 8263 0101000 | Black | Reel | 1,000 ft | 612825356004 |
| 8263 010U1000 | Black | UnReel | 1,000 ft | 612825358718 |
| Footnote: | C – CRATE REEL PUT-UP. |
History
| Update and Revision: | Revision Number: 0.411 Revision Date: 12-19-2022 |