Product Overview
| Suitable Applications: | solderable magnet wire |
Physical Characteristics (Overall)
| AWG | Stranding | Material | No. of Conductors |
|---|---|---|---|
| 24 | Solid | BC – Bare Copper | 1 |
| Conductor Count: | 1 |
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|---|---|
| PUR/Nylon – Polyurethane + Nylon | 0.0217 in | 0.001 in |
Construction and Dimensions
| Min Increase in OD: | 0.001 in |
Electrical Characteristics
| Nominal Conductor DCR |
|---|
| 25.7 Ohm/1000ft |
| Max. Recommended Current [A] |
|---|
| Single conductor in free air @ 30ºC: 0.6 A |
| Breakdown Voltage |
|---|
| 2425 V Minimum (at Room Temperature) |
Temperature Range
| Non-UL Temp Rating: | 130°C |
Mechanical Characteristics
| Approximate Length: | 404 ft |
| Turns Per Linear Inch: | 46.9 |
| Turns Per Square Inch: | 2200 |
| Bulk Cable Weight: | 1.24 lbs/1000ft |
| Min. Bend Radius/Minor Axis: | 0.09 in |
Standards
| Military Compliance: | J-W-1177/9 |
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2003/96/EC (BFR): | Yes |
| EU Directive 2011/65/EU (RoHS 2): | Yes |
| EU Directive 2012/19/EU (WEEE): | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment): | Yes |
| EU Directive Compliance: | EU Directive 2003/11/EC (BFR) |
| EU CE Mark: | Yes |
| CA Prop 65: | Yes |
| MII Order #39 (China RoHS): | Yes |
Flammability, LS0H, Toxicity Testing
| UL voltage rating: | N/A |
Plenum/Non-Plenum
| Plenum (Y/N): | No |
Related Part Numbers
| Item # | Color | Put-Up Type | Length | UPC |
|---|---|---|---|---|
| 8052 | None | Reel | 1 ft | 612825194484 |
History
| Update and Revision: | Revision Number: 0.382 Revision Date: 05-05-2023 |